2D soot volume fraction imaging in an ethylene diffusion flame by two-color laser induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics (Contributo in atti di convegno)

Type
Label
  • 2D soot volume fraction imaging in an ethylene diffusion flame by two-color laser induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics (Contributo in atti di convegno) (literal)
Anno
  • 2007-01-01T00:00:00+01:00 (literal)
Alternative label
  • De Iuliis S., Migliorini F., Cignoli F., Zizak G. (2007)
    2D soot volume fraction imaging in an ethylene diffusion flame by two-color laser induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics
    in International Symposium on Combustion, Heidelberg
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • De Iuliis S., Migliorini F., Cignoli F., Zizak G. (literal)
Pagina inizio
  • 869 (literal)
Pagina fine
  • 876 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 31 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#volumeInCollana
  • 31 (literal)
Rivista
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • IENI-CNR (literal)
Titolo
  • 2D soot volume fraction imaging in an ethylene diffusion flame by two-color laser induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics (literal)
Abstract
  • The two-color laser-induced incandescence (2C-LII) technique can be used for soot volume fraction measurements with no use of a reference flame of known soot concentration. In this work we have exploited the 2C-LII technique with the development of a two-dimensional imaging arrangement. By utilizing an IR pulsed laser, a laser sheet with sharp edges, and controlled fluence, the maximum soot temperature was verified to be around 4000 K in all the investigated regions of an ethylene diffusion flame. The calibrationfree 2D 2C-LII arrangement was then feasible and applied for soot imaging. Verification of the soot volume fraction measurements was carried out by comparison with other techniques such as ''point'' 2C-LII, laser extinction, 2D extinction, and 2D two-color emission techniques. Agreements and some discrepancies are discussed. (literal)
Editore
Prodotto di
Autore CNR

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
data.CNR.it