http://www.cnr.it/ontology/cnr/individuo/prodotto/ID58120
Absolute measurement of the S(0) and S(1) lines in the electric quadrupole fundamental band of D2 around 3 µm (Articolo in rivista)
- Type
- Label
- Absolute measurement of the S(0) and S(1) lines in the electric quadrupole fundamental band of D2 around 3 µm (Articolo in rivista) (literal)
- Anno
- 2010-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1063/1.3493393 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Maddaloni P.; Malara P.; De Tommasi E.; De Rosa M.; Ricciardi I.; Gagliardi G.; Tamassia F.; Di Lonardo G.; De Natale P. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Istituto Nazionale di Ottica (INO)-Consiglio Nazionale Delle Ricerche (CNR), Comprensorio A. Olivetti, Via Campi Flegrei, Pozzuoli, Napoli 34-80078, Italy; Dipartimento di Chimica Fisica e Inorganica, Università di Bologna, Viale del Risorgimento, Bologna 4-40136, Italy (literal)
- Titolo
- Absolute measurement of the S(0) and S(1) lines in the electric quadrupole fundamental band of D2 around 3 µm (literal)
- Abstract
- The electric quadrupole fundamental (v=1 <- 0) band of molecular deuterium around 3 mu m is accessed by cavity ring-down spectroscopy using a difference-frequency-generation source linked to the Cs-clock primary standard via an optical frequency comb synthesizer. An absolute determination of the line position and strength is reported for the first two transitions (J=2 <- 0 and J=3 <- 1) of the S branch. An accuracy of 6 x 10(-8) is achieved for the line-center frequencies, which improves by a factor 20 previous experimental results [A. R. W. McKellar and T. Oka, Can. J. Phys. 56, 1315 (1978)]. The line strength values, measured with 1% accuracy, are used to retrieve the quadrupole moment matrix elements which are found in good agreement with previous theoretical calculations [A. Birnbaum and J. D. Poll, J. Atmos. Sci. 26, 943 (1969); J. L. Hunt, J. D. Poll, and L. Wolniewicz, Can. J. Phys. 62, 1719 (1984)]. (C) 2010 American Institute of Physics. [doi:10.1063/1.3493393] (literal)