Frequency-comb-referenced quantum-cascade laser at 4.4 um (Articolo in rivista)

Type
Label
  • Frequency-comb-referenced quantum-cascade laser at 4.4 um (Articolo in rivista) (literal)
Anno
  • 2007-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1364/OL.32.000988 (literal)
Alternative label
  • Bartalini S., Cancio P., Giusfredi G., Mazzotti D., De Natale P., Borri S., Galli I., Leveque T., Gianfrani L. (2007)
    Frequency-comb-referenced quantum-cascade laser at 4.4 um
    in Optics letters
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Bartalini S., Cancio P., Giusfredi G., Mazzotti D., De Natale P., Borri S., Galli I., Leveque T., Gianfrani L. (literal)
Pagina inizio
  • 988 (literal)
Pagina fine
  • 990 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 32 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 8 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR - Istituto Nazionale di Ottica Applicata, Largo E. Fermi 6, 50125 Firenze, Italy; European Laboratory for Non-linear Spectroscopy, Via Carrara 1, 50019 Sesto Fiorentino FI, Italy; Dipartimento di Fisica, Università di Firenze, Via Sansone 1, 50125 Firenze FI, Italy; Ecole Supérieure d’Optique, Institut d’Optique Théorique et Appliquée, 91403 Orsay Cedex, France Dipartimento di Scienze Ambientali, Seconda Università di Napoli and CNISM - Unità Napoli 2, Via Vivaldi 43, 81100 Caserta, Italy (literal)
Titolo
  • Frequency-comb-referenced quantum-cascade laser at 4.4 um (literal)
Abstract
  • We report what we believe to be the first absolute frequency measurement performed using a quantum-cascade laser (QCL) referenced to an optical frequency comb synthesizer (OFCS). A QCL at 4.43 um has been used for producing near-infrared radiation at 858 nm by means of sum-frequency generation with a Nd:YAG source in a periodically poled lithium niobate nonlinear crystal. The absolute frequency of the QCL source has been measured by detecting the beat note between the sum frequency and a diode laser at the same wavelength, while both the Nd:YAG and the diode laser were referenced to the OFCS. Doppler-broadened line profiles of 13CO2 molecular transitions have been recorded with such an absolute frequency reference. (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it