http://www.cnr.it/ontology/cnr/individuo/prodotto/ID55320
CFD analysis of the flow-field scale-up influence on the electrodes performance in a PEFC (Articolo in rivista)
- Type
- Label
- CFD analysis of the flow-field scale-up influence on the electrodes performance in a PEFC (Articolo in rivista) (literal)
- Anno
- 2005-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.jpowsour.2004.12.054 (literal)
- Alternative label
G. Squadrito ; O. Barbera ; I. Gatto ; G. Giacoppo ; F. Urbani ; E. Passalacqua (2005)
CFD analysis of the flow-field scale-up influence on the electrodes performance in a PEFC
in Journal of power sources (Print); ELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS, AMSTERDAM (Paesi Bassi)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- G. Squadrito ; O. Barbera ; I. Gatto ; G. Giacoppo ; F. Urbani ; E. Passalacqua (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- CNR-ITAE, via Salita S. Lucia sopra Contessen. 5, 98126 S. Lucia, Messina, Italy (literal)
- Titolo
- CFD analysis of the flow-field scale-up influence on the electrodes performance in a PEFC (literal)
- Abstract
- A computational fluid dynamic (CFD) analysis was used as a useful tool to obtain numerical relationships among similar flow-field designs
having different active areas. Assuming that, at fixed current density, the porous layer velocity distribution calculated for the smallest size
geometry was the optimal, a scale-up methodology has been proposed and implemented in software. It allows acquisition of the scaled-up
flow-field by multiplying the reference cell parameters by suitable factors (scale factors). A calibration methodology has also been proposed
by the introduction of a feedback factor evaluated by CFD analysis. A first application of this procedure has been carried out to scale-up a
5-125 cm2 cell. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di