Energy dispersive X-ray diffraction spectroscopy for rapid estimation of calcite in copper ores (Articolo in rivista)

Type
Label
  • Energy dispersive X-ray diffraction spectroscopy for rapid estimation of calcite in copper ores (Articolo in rivista) (literal)
Anno
  • 2009-01-01T00:00:00+01:00 (literal)
Alternative label
  • Escárate P., Bailo D., Guesalaga A., Rossi Albertini V. (2009)
    Energy dispersive X-ray diffraction spectroscopy for rapid estimation of calcite in copper ores
    in Minerals engineering
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Escárate P., Bailo D., Guesalaga A., Rossi Albertini V. (literal)
Pagina inizio
  • 566 (literal)
Pagina fine
  • 571 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 22 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
  • http://dx.doi.org/10.1016/j.mineng.2009.01.009 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Departamento de Ingeniería Eléctrica, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile Istituto di Struttura della Materia, CNR, Via Fosso del Cavaliere 100, Rome, Italy (literal)
Titolo
  • Energy dispersive X-ray diffraction spectroscopy for rapid estimation of calcite in copper ores (literal)
Abstract
  • This article presents a novel technique for measuring the concentration of calcite in copper ore samples using energy dispersive X-ray diffraction (ED-XRD). The results are compared with ultraviolet fluorescence spectroscopy (UVF) for the same group of samples. This approach substantially shortens the measuring time with respect to the current laboratory procedures from 300 min down to 15 min and 9 min for energy dispersive X-ray diffraction and ultraviolet fluorescence spectroscopy, respectively, while preserving a good accuracy level (RMSE < 0.577). The models used for data processing were calibrated and validated for both techniques via the correlation coefficients (View the R2c source and View the R2v source), the error of prediction (RMSEP) and the error of calibration (RMSEC). View the R2v source values between 0.88 and 0.94 were obtained for UVF and ED-XRD data, respectively. The calibration and validation were performed for calcite concentration ranges of 3.4–10.7% in the case of UVF and 2.9–7.6% for ED-XRD. (literal)