A new application of diacetyl monoxime method to the automated determination of dissolved urea in seawater. (Articolo in rivista)

Type
Label
  • A new application of diacetyl monoxime method to the automated determination of dissolved urea in seawater. (Articolo in rivista) (literal)
Anno
  • 2004-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1007/s00227-004-1366-y (literal)
Alternative label
  • Cozzi S. (2004)
    A new application of diacetyl monoxime method to the automated determination of dissolved urea in seawater.
    in Marine biology (Berl.); Springer, Dordrecht (Paesi Bassi)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Cozzi S. (literal)
Pagina inizio
  • 843 (literal)
Pagina fine
  • 848 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • DOI 10.1007/s00227-004-1366-y (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.springerlink.com/content/0025-3162/ (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 145 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 6 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 4 (literal)
Note
  • Google Scholar (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR I.S.MAR., Sede di Trieste, Viale Romolo Gessi 2, 34123 Trieste, Italy (literal)
Titolo
  • A new application of diacetyl monoxime method to the automated determination of dissolved urea in seawater. (literal)
Abstract
  • A new application of the diacetyl monoxime method for the determination of dissolved urea in seawater is presented, based on the Alpkem autoanalyzer (OI, Analytical). This system has several advantages over automated methods previously described in the literature. The urea cartridge can be easily built using nut/ferrule connections, and the external thermostatic bath is not required. The system is set up to operate at low urea concentrations (0–3 mu M urea), but it is linear up to 100 mu M urea. The sample volume needed for analysis is 0.4 ml, and the rate of analysis is 25 samples h)1. The precision of analysis (CV) of seawater samples is 2.1% at 0.50 mu M urea, and the detection limit is 0.02 mu M urea. The interference on the colorimetric measurement due to formation of Brij-35 aggregate in strongly acidic media was eliminated by substituting this wetting agent with hexadecyl–trimethyl–ammonium bromide; thus, this method is suitable for other autoanalyzer technologies that use small-diameter transmission tubes and small-sized spectrophotometric flowcells. (literal)
Editore
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
Insieme di parole chiave di
data.CNR.it