Detection of immune complexes by matrix-assisted laser desorption/ionization mass spectrometry. (Articolo in rivista)

Type
Label
  • Detection of immune complexes by matrix-assisted laser desorption/ionization mass spectrometry. (Articolo in rivista) (literal)
Anno
  • 2003-01-01T00:00:00+01:00 (literal)
Alternative label
  • Schlosser G, Pocsfalvi G, Malorni A, Puerta A, de Frutos M, Vekey K. (2003)
    Detection of immune complexes by matrix-assisted laser desorption/ionization mass spectrometry.
    in RCM. Rapid communications in mass spectrometry
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Schlosser G, Pocsfalvi G, Malorni A, Puerta A, de Frutos M, Vekey K. (literal)
Pagina inizio
  • 2741 (literal)
Pagina fine
  • 2747 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • 3 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 17 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#descrizioneSinteticaDelProdotto
  • In questo lavoro la tecnica di MALDI-MS è stata impiegata per lo studio in fase gassosa di un immunocomplesso formato dalla beta-lattoglobulina e da anticorpi policlonali per essa specifici. L'analisi, i cui parametri critici sono rappresentati dal pH neutro della soluzione in cui si viene a formare il complesso e l'impiego come matrice di acido sinapinico preparato secondo il metodo dried-droplet, rivela che ogni molecola di anticorpo si lega specificamente ad una o due molecole di antigene. La specificità del legame viene confermata da saggi competitivi nei i quali non solo si osserva la presenza del segnale relativo all'immunocomplesso, ma anche una diminuzione di quello relativo alla lattoglobulina libera, indipendentemente dalla concentrazione della proteina di controllo. (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Chemical Research Center, Hungarian Academy of Sciences, Budapest, Hungary Proteomic and Biomolecular Mass Spectrometry Center (CESMA-ProBio), Institute of Food Science and Technology, C.N.R., Avellino, Italy Institute of Organic Chemistry, C.S.I.C., Madrid, Spain (literal)
Titolo
  • Detection of immune complexes by matrix-assisted laser desorption/ionization mass spectrometry. (literal)
Abstract
  • Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to detect an immune complex formed between beta-lactoglobulin and polyclonal anti-beta-lactoglobulin antibody in the gas phase. The most important experimental parameters to detect such a specific antibody-antigen complex by MALDI were the use of solutions at near-neutral pH and of sinapinic acid matrix prepared by the dried-droplet method. Under such conditions, predominantly one but also two molecules of antigen protein were complexed by the antibody. Specific formation of the antibody-antigen complex was confirmed by performing competitive reactions. Addition of antibody to a 1:1 mixture of beta-lactoglobulin and one control protein resulted not only in the appearance of the expected antibody-antigen complex, but also in a strong decrease in the free beta-lactoglobulin signal, while the abundance of the control protein was not influenced. Copyright 2003 John Wiley & Sons, Ltd. (literal)
Prodotto di
Autore CNR

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
data.CNR.it