http://www.cnr.it/ontology/cnr/individuo/prodotto/ID44897
Accuracy of measurements of turbulent phenomena in the Surface Layer with an ultrasonic anemometer (Articolo in rivista)
- Type
- Label
- Accuracy of measurements of turbulent phenomena in the Surface Layer with an ultrasonic anemometer (Articolo in rivista) (literal)
- Anno
- 2006-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1175/JTECH1881.1 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Contini D.; Donateo A.; Belosi F. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Contini D. e Donateo A.:
Istituto di Scienze dell'Atmosfera e del Clima, UOS di Lecce, Italy
Belosi F.:
Istituto di Scienze dell'Atmosfera e del Clima, Bologna, Italy (literal)
- Titolo
- Accuracy of measurements of turbulent phenomena in the Surface Layer with an ultrasonic anemometer (literal)
- Abstract
- Ultrasonic anemometers are widely used to investigate turbulence in the surface layer. Some of their
advantages are high-frequency sampling, the ability to work for long periods without a resident operator
(even in adverse meteorological conditions), and their calibration related only to design parameters. In this
paper an analysis of the random uncertainty associated with ultrasonic anemometer measurements is
reported. The analysis is based on a statistical procedure that compares the simultaneous data taken with
two identical anemometers operating in nominally identical conditions. Postprocessing of data has been
carried out in different reference systems in order to evaluate how the random uncertainties change
according to the postprocessing procedure used. Results show that uncertainty on wind velocity decreases
with averaging time, and it can be as low as 1 cm s?1 for a typical averaging time of 30 min. The random
uncertainty on average vertical wind velocity ?w? could also be as low as 1 cm s?1, and it is very sensitive
to the effects of vertical misalignment. The analysis is based on six different measurement sets in which the
anemometers have been deployed on a single mast or in two separate masts with and without additional
detectors placed near the anemometers themselves. Results indicate that the uncertainty of all the measured
parameters increases when the anemometer is used in configurations in which they are placed on separate
masts. Several parameters also show an additional increase of uncertainty if other detectors are placed
nearby. The relative random uncertainty on momentum and sensible heat fluxes, for typical averaging time,
can be as low as 6%-7% and it could increase to a factor of 2-3 when they are placed on separate masts.
Only small effects due to the influence of flow distortions caused by the presence of additional sensors have
been found on fluxes and are mainly related to sensible heat flux. (literal)
- Prodotto di
- Autore CNR
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi