http://www.cnr.it/ontology/cnr/individuo/prodotto/ID42819
Experimental study of filtration system performance of natural gas in urban transmission and distribution network: A case study on the city of Kerman, Iran (Articolo in rivista)
- Type
- Label
- Experimental study of filtration system performance of natural gas in urban transmission and distribution network: A case study on the city of Kerman, Iran (Articolo in rivista) (literal)
- Anno
- 2011-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.fuel.2010.10.009 (literal)
- Alternative label
Azadi, M; Mohebbi, A; Scala, F, Soltaninejad S (2011)
Experimental study of filtration system performance of natural gas in urban transmission and distribution network: A case study on the city of Kerman, Iran
in Fuel (Guildf.)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Azadi, M; Mohebbi, A; Scala, F, Soltaninejad S (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Department of Chemical Engineering, College of Engineering, Shahid Bahonar University of Kerman
Istituto di Ricerche sulla Combustione - CNR
Gas Company of Kerman Province (literal)
- Titolo
- Experimental study of filtration system performance of natural gas in urban transmission and distribution network: A case study on the city of Kerman, Iran (literal)
- Abstract
- Suspended particles are well known to cause serious problems in natural gas pipelines and related equipment.
In this study, suspended particles in the natural gas transmission and distribution network of the
city of Kerman, Iran were investigated. Particle concentration and size distribution were measured, under
isokinetic condition, in different locations of the natural gas pipeline network. Additional particle characterization
was carried out through SEM/EDX and XRD analysis. The filtration performance was found
to be rather inefficient according to the particle concentration in the natural gas flow, although it
decreased along the pipeline to the end of the network. Larger particles were more likely to exist at
the network entrance with respect to the network pipeline exit. The results of particle characterization
confirmed the presence of corrosion products in the suspended particles. (literal)