http://www.cnr.it/ontology/cnr/individuo/prodotto/ID4113
Responses of peptide-specific T cells to stimulation with polystyrene beads carrying HLA class I molecules loaded with single peptides. (Articolo in rivista)
- Type
- Label
- Responses of peptide-specific T cells to stimulation with polystyrene beads carrying HLA class I molecules loaded with single peptides. (Articolo in rivista) (literal)
- Anno
- 2004-01-01T00:00:00+01:00 (literal)
- Alternative label
Chersi A, Galati R, Accapezzato D, Francavilla V, Barnaba V, Butler RH, Tanigaki N. (2004)
Responses of peptide-specific T cells to stimulation with polystyrene beads carrying HLA class I molecules loaded with single peptides.
in Journal of immunological methods (Print)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Chersi A, Galati R, Accapezzato D, Francavilla V, Barnaba V, Butler RH, Tanigaki N. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#descrizioneSinteticaDelProdotto
- Pubblicazione su rivista internazionale (literal)
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Titolo
- Responses of peptide-specific T cells to stimulation with polystyrene beads carrying HLA class I molecules loaded with single peptides. (literal)
- Abstract
- Cell-sized microbeads carrying single peptide-loaded HLA class I molecules were prepared for HLA-A2 and HLA-B7 by a simple procedure which transfers single peptide-loaded HLA class I molecules from cultured cells to polystyrene beads using anti-peptide antibodies directed to an intracellular segment of HLA-A alpha chains. The surface density of peptide-loaded HLA class I molecules on beads was comparable to that on the peptide-loaded cells. HLA-A2 beads loaded with an HCV peptide HCV1073 were tested for stimulation activity on an HCV1073-specific CD8+ T cell clone NS3-1. A substantial level of gamma-IFN production was induced. The stimulation was peptide-specific. The efficiency was dependent on the bead concentration and the surface HLA class I density on beads and enhanced significantly by co-coupling of anti-CD28 to peptide-loaded beads. The peptide-loading efficiency on HLA class I molecules and the transfer efficiency of HLA class I molecules to polystyrene beads were reasonably high for HLA-A2 and HLA-B7. Thus, polystyrene beads carrying these single peptide-loaded HLA class I molecules are potentially useful in further analysis of the co-stimulatory or inhibitory factors involved in CD8+ T cell responses and eventually in detection of cytotoxic T cells in PBLs. (literal)
- Prodotto di
- Autore CNR
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi