Fast analysis of complex metallic alloys by double-pulse time-integrated laser-induced breakdown spectroscopy (Articolo in rivista)

Type
Label
  • Fast analysis of complex metallic alloys by double-pulse time-integrated laser-induced breakdown spectroscopy (Articolo in rivista) (literal)
Anno
  • 2009-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.sab.2009.07.037 (literal)
Alternative label
  • Sorrentino F., Carelli G., Francesconi F., Francesconi M., Marsili P., Cristoforetti G., Legnaioli S., Palleschi V., Tognoni E. (2009)
    Fast analysis of complex metallic alloys by double-pulse time-integrated laser-induced breakdown spectroscopy
    in Spectrochimica acta. Part B, Atomic spectroscopy; Elsevier, Amsterdam (Paesi Bassi)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Sorrentino F., Carelli G., Francesconi F., Francesconi M., Marsili P., Cristoforetti G., Legnaioli S., Palleschi V., Tognoni E. (literal)
Pagina inizio
  • 1068 (literal)
Pagina fine
  • 1072 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.pi.iccom.cnr.it/user/13/biblio (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 64 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 10 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Marwan Technology s.r.l., Spin-off University of Pisa Largo Pontecorvo 3, 56127 Pisa, Italy Applied Laser Spectroscopy Laboratory, IPCF/CNR - Via G.Moruzzi 1, 56124 Pisa, Italy (literal)
Titolo
  • Fast analysis of complex metallic alloys by double-pulse time-integrated laser-induced breakdown spectroscopy (literal)
Abstract
  • Results are reported on the application of double-pulse Laser-Induced Breakdown Spectroscopy (LIBS) for fast analysis of complex metallic alloys. The approach followed for the determination of the composition of the alloys is based on the time-integrated acquisition of LIBS spectra emitted by plasmas induced by collinear double-pulse laser excitation. The spectra are analysed using the Partial Least Squares method, which allows the determination of sample composition even in the presence of strong spectral interferences. The results shown indicate the possibility of measuring the composition of complex metallic alloys in very short times and using relatively cheap LIBS instrumentation. (literal)
Editore
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Editore di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it