http://www.cnr.it/ontology/cnr/individuo/prodotto/ID39776
Characterization of a collinear double pulse Laser-Induced Plasma at several ambient gas pressures by spectrally- and time-resolved imaging (Articolo in rivista)
- Type
- Label
- Characterization of a collinear double pulse Laser-Induced Plasma at several ambient gas pressures by spectrally- and time-resolved imaging (Articolo in rivista) (literal)
- Anno
- 2005-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1007/s00340-005-1758-9 (literal)
- Alternative label
G.Cristoforetti, S. Legnaioli, V. Palleschi, A. Salvetti and E.Tognoni (2005)
Characterization of a collinear double pulse Laser-Induced Plasma at several ambient gas pressures by spectrally- and time-resolved imaging
in Applied physics. B, Lasers and optics (Print); Springer, New York (Stati Uniti d'America)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- G.Cristoforetti, S. Legnaioli, V. Palleschi, A. Salvetti and E.Tognoni (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- IPCF - UOS di Pisa (literal)
- Titolo
- Characterization of a collinear double pulse Laser-Induced Plasma at several ambient gas pressures by spectrally- and time-resolved imaging (literal)
- Abstract
- A collinear double pulse laser-induced plasma was characterised by means of a spectrally and time resolved imaging technique. The beams of two Q-switched Nd:YAG lasers were focused on a brass target in a vacuum chamber to form the plasma. The plume emission intensity and spatial distribution were recorded with temporal resolution using an intensified CCD. Using a set of interference filters, we collected images of the emission from the major target components as well as from oxygen. Both the laser inter-pulse separation (in the range between 0 and 10 ?s) and the ambient air pressure value (in the range between 105 and 10 Pa) were varied during the experiment. At atmospheric pressure, an enhancement of
the line emission from the target elements was observed for delayed laser pulses compared to coincident pulses. However, this enhancement effect tends to fall at low pressure values, and a decrease of the signal is observed for pressures under about 104 Pa. Moreover, it was observed that the evaluation of the enhancement factor strongly depends on the detector field of view. The propagation of the emitting plume was also
studied at several pressures and inter-pulse delays. (literal)
- Editore
- Prodotto di
- Autore CNR
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di