http://www.cnr.it/ontology/cnr/individuo/prodotto/ID39208
Complex Response Function of Magnetic Resonance Spectrometers (Articolo in rivista)
- Type
- Label
- Complex Response Function of Magnetic Resonance Spectrometers (Articolo in rivista) (literal)
- Anno
- 2002-01-01T00:00:00+01:00 (literal)
- Alternative label
Annino G., Cassettari M., Fittipaldi M., Martinelli M. (2002)
Complex Response Function of Magnetic Resonance Spectrometers
in Journal of magnetic resonance (San Diego, Calif., 1997 : Print)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Annino G., Cassettari M., Fittipaldi M., Martinelli M. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#descrizioneSinteticaDelProdotto
- E stata sviluppata una analisi teorica della fase e dellampiezza dellonda elettromagnetica rivelata alluscita di uno spettrometro per risonanza magnetica. La modellizzazione proposta, sviluppata inizialmente per spettrometri basati su risuonatore ad onda viaggiante, è stata generalizzata al caso di risuonatori ad onda stazionaria. I casi di rivelazione mediante rivelatore scalare e vettoriale sono stati analizzati in dettaglio, così come i regimi di risposta lineare per rivelatori scalari con legge di risposta arbitraria. (literal)
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1, 2, 4: Istituto per i Processi Chimico-Fisici, CNR, 3: Huygens Laboratory, University of Leiden, Leiden (The Netherlands) (literal)
- Titolo
- Complex Response Function of Magnetic Resonance Spectrometers (literal)
- Abstract
- A vectorial analysis of magnetic resonance spectrometers, based on traveling wave resonators and including the reference arm and the automatic control of frequency, has been developed. The proposed modeling, valid also for stationary wave resonators, gives the response function of the spectrometer for any working condition, including scalar detectors with arbitrary response law and arbitrary excitation frequency. The purely dispersive and purely absorptive linear responses are discussed in detail for different scalar detectors. The developed approach allows to optimize the performances of the spectrometer and to obtain the intrinsic lineshape of the sample in a very broad range of working conditions. More complex setups can be modeled following the proposed scheme. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di