http://www.cnr.it/ontology/cnr/individuo/prodotto/ID328449
Uncertainty of Façade Sound Insulation in Buildings by a Round Robin Test (Articolo in rivista)
- Type
- Label
- Uncertainty of Façade Sound Insulation in Buildings by a Round Robin Test (Articolo in rivista) (literal)
- Anno
- 2015-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.apacoust.2015.03.002 (literal)
- Alternative label
C.Scrosati, F.Scamoni, G.Zambon (2015)
Uncertainty of Façade Sound Insulation in Buildings by a Round Robin Test
in Applied acoustics; Elsevier Ltd, Oxford (Regno Unito)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- C.Scrosati, F.Scamoni, G.Zambon (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- C.Scrosati e F.Scamoni: ITC-CNR, Construction Technologies Institute of the National Research Council of Italy, Milano, Italy
G.Zambon: DISAT, Department of Earth and Environmental Sciences of the University of Milano - Bicocca, Milano, Italy (literal)
- Titolo
- Uncertainty of Façade Sound Insulation in Buildings by a Round Robin Test (literal)
- Abstract
- The uncertainty of field measurements of a façade was evaluated by a Round Robin Test (RRT) conducted in a full-scale experimental building at the Construction Technologies Institute of the National Research Council of Italy (ITC-CNR). Each of the 9 teams involved in the RRT replicated the tests 5 times, for a total of 45 measurements, while reverberation time was repeated 110 times. Both for façade sound insulation and reverberation time the main variations in the one-third octave bands were found in the low frequencies
range. The study was also focused on the evaluation of single number quantities (SNQs) and their uncertainties. Single number quantities were evaluated in both narrow (from 100 to 3150 Hz) and extended (from 50 to 5000 Hz) range. Concerning the SNQs and their uncertainties, no significant differences were observed whether the low frequencies were included or not, unlike the case of airborne sound insulation (investigated in the first part of this study). The uncertainty results were compared with the
relevant standards and with literature results. Based on these comparisons, it was highlighted that the standard deviation of reproducibility of façade elements is not adequately reflected in the ISO 12999-1 and further research is needed to specify the in situ standard deviation of reproducibility for façade elements. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Editore di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di