In vitro ultrasound characterization of human proximal femur microstructure and comparison with micro-CT data (Contributo in atti di convegno)

Type
Label
  • In vitro ultrasound characterization of human proximal femur microstructure and comparison with micro-CT data (Contributo in atti di convegno) (literal)
Anno
  • 2014-01-01T00:00:00+01:00 (literal)
Alternative label
  • M. Peccarisi, T. De Marco, L. Spedicato, A. Greco, F. Conversano, D. Panetta, G. Guido, V. Bottai, P. Salvadori and S. Casciaro (2014)
    In vitro ultrasound characterization of human proximal femur microstructure and comparison with micro-CT data
    in 3rd Imeko TC13 Symposium on Measurements in Biology and Medicine "New Frontiers in Biomedical Measurements", Lecce, Italy, 17-18 Aprile 2014
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • M. Peccarisi, T. De Marco, L. Spedicato, A. Greco, F. Conversano, D. Panetta, G. Guido, V. Bottai, P. Salvadori and S. Casciaro (literal)
Pagina inizio
  • 62 (literal)
Pagina fine
  • 66 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
  • Proceedings of the 3rd Imeko TC13 Symposium on Measurements in Biology and Medicine \"New Frontiers in Biomedical Measurements\" (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Echolight S.r.l., Lecce, Italy; National Research Council, Institute of Clinical Physiology, Lecce-Pisa, Italy; Clinica Ortopedica e Traumatologica II, University of Pisa, Pisa, Italy. (literal)
Titolo
  • In vitro ultrasound characterization of human proximal femur microstructure and comparison with micro-CT data (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 978-92-990073-5-8 (literal)
Abstract
  • An in vitro investigation based on Quantitative Ultrasound (QUS) has been carried out in this paper on a sample of human femoral head, aiming at microstructure characterization and bone quality assessment. Two QUS parameters, Integrated Reflection Coefficient (IRC) and Apparent Integrated Backscatter (AIB) were measured by accurately analyzing ultrasonic signals backscattered from the target bone when immersed in water and insonified at 2.25 MHz. In particular, US data were acquired from 22 different positions along the maximum section perpendicular to the axial direction (head-neck axis) of the target sample. The obtained data were compared with local structural properties gathered at each considered position from a high-resolution micro-computed tomography (microCT) scan of the same sample. A linear regression analysis showed an appreciable correlation between QUS parameters and some of the micro-structural parameters. As expected, IRC correlated better with cortical bone volume fraction (r = -0.53), and AIB with trabecular bone volume fraction (r = -0.60) and trabecular spacing (r = 0.47). These results are particularly encouraging in view of a possible clinical translation of the proposed approach for early osteoporosis diagnosis. (literal)