Spectral- and time-resolved optical mammography by means of a pulsed supercontinuum ligth source (Abstract/Poster in atti di convegno)

Type
Label
  • Spectral- and time-resolved optical mammography by means of a pulsed supercontinuum ligth source (Abstract/Poster in atti di convegno) (literal)
Anno
  • 2006-01-01T00:00:00+01:00 (literal)
Alternative label
  • Spinelli, Lorenzo; Bassi, Andrea; D'Andrea, Cosimo; Giusto, Arianna; Swartling, Johannes; Torricelli, Alessandro; Pifferi, Antonio; Cubeddu, Rinaldo (2006)
    Spectral- and time-resolved optical mammography by means of a pulsed supercontinuum ligth source
    in Biomedical Topical Meeting, BIOMED 2006, Fort Lauderdale, FL; United States, 19 March 2006
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Spinelli, Lorenzo; Bassi, Andrea; D'Andrea, Cosimo; Giusto, Arianna; Swartling, Johannes; Torricelli, Alessandro; Pifferi, Antonio; Cubeddu, Rinaldo (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • cited By 0; Conference of Biomedical Topical Meeting, BIO 2006 ; Conference Date: 19 March 2006 Through 19 March 2006; Conference Code:104795 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.scopus.com/record/display.url?eid=2-s2.0-84899136615&origin=inward (literal)
Rivista
Note
  • Scopu (literal)
  • Abstract (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Politecnico di Milano; University of Cambridge (literal)
Titolo
  • Spectral- and time-resolved optical mammography by means of a pulsed supercontinuum ligth source (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 1-55752-807-1 (literal)
Abstract
  • The clinical feasibility of time-resolved diffuse optical mammography exploiting a broad-band system is for the first time demonstrated. The instrument is based on supercontinuum light generated by a photonic crystal fiber as light source and on a parallel 32-channel timecorrelated single-photon-counting detection chain for the collection stage. The measurement time is kept as low as about 5-10 minutes, being in this way compliant for clinical application. First images performed on healthy volunteers are shown. Furthermore, the ability of the system to determine tissue constituents and structural parameters by a fully spectral analysis procedure has been tested. © 2006 Optical Society of America. (literal)
Prodotto di
Autore CNR

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
data.CNR.it