http://www.cnr.it/ontology/cnr/individuo/prodotto/ID317839
Preliminary results of the optical calibration for the Stereo Camera STC onboard the BepiColombo mission (Contributo in atti di convegno)
- Type
- Label
- Preliminary results of the optical calibration for the Stereo Camera STC onboard the BepiColombo mission (Contributo in atti di convegno) (literal)
- Anno
- 2014-01-01T00:00:00+01:00 (literal)
- Alternative label
V. Da Deppo, E. Martellato, E. Simioni, D. Borrelli, M. Dami, G. Aroldi, G. Naletto, I. Ficai Veltroni, G. Cremonese (2014)
Preliminary results of the optical calibration for the Stereo Camera STC onboard the BepiColombo mission
in ICSO 2014 - International Conference on Space Optics, Tenerife - Canary Islands - Spain, 7-10 October 2014
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- V. Da Deppo, E. Martellato, E. Simioni, D. Borrelli, M. Dami, G. Aroldi, G. Naletto, I. Ficai Veltroni, G. Cremonese (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- CNR-IFN UOS Padova LUXOR
INAF - Osservatorio Astronomico di Padova
Dipartimento di Fisica e Astronomia - Università di Padova
Selex ES
Dipartimento di Ingegneria dell'Informazione Università di Padova
CISAS - Università di Padova (literal)
- Titolo
- Preliminary results of the optical calibration for the Stereo Camera STC onboard the BepiColombo mission (literal)
- Abstract
- BepiColombo is one of the cornerstone missions of the European Space Agency dedicated to the exploration
of the planet Mercury and it is expected to be launched in July 2016.
One of the BepiColombo instruments is the STereoscopic imaging Channel (STC), which is a channel of the
Spectrometers and Imagers for MPO BepiColombo Integrated Observatory SYStem (SIMBIOSYS) suite: an
integrated system for imaging and spectroscopic investigation of the Mercury surface. STC main aim is the 3D
global mapping of the entire surface of the planet Mercury during the BepiColombo one year nominal mission.
The STC instrument consists in a novel concept of stereocamera: two identical cameras (sub-channels)
looking at ±20° from nadir which share most of the optical components and the detector. Being the detector a
2D matrix, STC is able to adopt the push-frame acquisition technique instead of the much common push-broom
one.
The camera has the capability of imaging in five different spectral bands: one panchromatic and four
intermediate bands, in the range between 410 and 930 nm.
To avoid mechanisms, the technical solution chosen for the filters is the single substrate stripe-butted filter in
which different glass pieces, with different transmission properties, are glued together and positioned just in
front of the detector.
The useful field of view (FoV) of each sub-channel, though divided in 3 strips, is about 5.3° x 3.2°. The
optical design, a modified Schmidt layout, is able to guarantee that over all the FoV the diffraction Ensquared
Energy inside one pixel of the detector is of the order of 70-80%.
To effectively test and calibrate the overall STC channel, an ad hoc Optical Ground Support Equipment has
been developed. Each of the sub-channels has to be separately calibrated, but also the data of one sub-channel
have to be easily correlated with the other one.
In this paper, the experimental results obtained by the analysis of the data acquired during the preliminary onground
optical calibration campaign on the STC Flight Model will be presented.
This analysis shows a good agreement between the theoretical expected performance and the experimental
results. (literal)
- Prodotto di
- Autore CNR
Incoming links:
- Prodotto
- Autore CNR di