Micro flow cytometer with self-aligned 3D hydrodynamic focusing (Articolo in rivista)

Type
Label
  • Micro flow cytometer with self-aligned 3D hydrodynamic focusing (Articolo in rivista) (literal)
Anno
  • 2015-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1364/BOE.6.000054 (literal)
Alternative label
  • Testa, Genni; Persichetti, Gianluca; Bernini, Romeo (2015)
    Micro flow cytometer with self-aligned 3D hydrodynamic focusing
    in Biomedical optics express
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Testa, Genni; Persichetti, Gianluca; Bernini, Romeo (literal)
Pagina inizio
  • 54 (literal)
Pagina fine
  • 62 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.scopus.com/record/display.url?eid=2-s2.0-84920527708&origin=inward (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 6 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 9 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 1 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopu (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Consiglio Nazionale delle Ricerche (CNR) (literal)
Titolo
  • Micro flow cytometer with self-aligned 3D hydrodynamic focusing (literal)
Abstract
  • A micro flow cytometer with a single step 3D hydrodynamic flow focusing has been developed. The proposed design is capable to create a single-file particle stream that is self-aligned with an integrated optical fiber-based detection system, regardless of the flow rate ratio between the focusing and core liquids. The design approach provides the ability to adjust the stream size while keeping the position of the focused stream centered with respect to the focusing channel. The device has been fabricated by direct micro milling of PMMA sheets. Experimental validation of the hydrodynamic sheath focusing effect has been presented and sample stream with tuneable size from about 18 to 50 mu m was measured. Flow cytometry measurements have been performed by using 10-23 mu m fluorescent particles. From the analysis of the signals collected at each transit event we can confirm that the device was capable to align and measure microparticles with a good coefficient of variance. (C) 2014 Optical Society of America (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it