http://www.cnr.it/ontology/cnr/individuo/prodotto/ID315319
Cavity and quartz enhanced photo-acoustic mid-IR sensor (Contributo in atti di convegno)
- Type
- Label
- Cavity and quartz enhanced photo-acoustic mid-IR sensor (Contributo in atti di convegno) (literal)
- Anno
- 2014-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1117/12.2042246 (literal)
- Alternative label
Patimisco, P.; Borri, S.; Scamarcio, G.; Spagnolo, V.; Galli, I.; Giusfedi, G.; Mazzotti, D.; De Natale, P. (2014)
Cavity and quartz enhanced photo-acoustic mid-IR sensor
in Conference on Quantum Sensing and Nanophotonic Devices XI, San Francisco, CA, FEB 02-06, 2014
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Patimisco, P.; Borri, S.; Scamarcio, G.; Spagnolo, V.; Galli, I.; Giusfedi, G.; Mazzotti, D.; De Natale, P. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
- Quantum Sensing and Nanophotonic Devices XI (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#volumeInCollana
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Istituto Nazionale di Ottica (INO) - CNR
European Laboratory for Non-linear Spectroscopy (LENS)
Department of Electrical and Computer Engineering, Rice University
Istituto di Fotonica e Nanotecnologie (IFN) - CNR
Dipartimento Interateneo di Fisica, Universit?à degli Studi di Bari e Politecnico di Bari (literal)
- Titolo
- Cavity and quartz enhanced photo-acoustic mid-IR sensor (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
- 978-0-8194-9906-6 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#curatoriVolume
- Razeghi, M; Tournie, E; Brown, GJ (literal)
- Abstract
- We report on a novel intracavity quartz enhanced photoacoustic (I-QEPAS) gas sensing technique taking advantage from both the high Q-factor of standard tuning forks and the power build-up of a high-finesse optical resonator. This first prototype employs a distributed feedback quantum cascade laser operating at 4.3 mu m. CO2 has been selected as gas target. Preliminary results demonstrate an improved sensitivity, close to the cavity enhancement factor (similar to 500) times the optical coupling efficiency (about 0.5), with respect to standard QEPAS technique. The detection limit was pulled from 7 ppm (obtained with standard QEPAS) down to 32 ppb, corresponding to normalized noise-equivalent absorption in the 10(-9) W.cm(-)1.Hz(- 1/2) range. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di