Vacuum facility for calibration of space instrumentation in cleanroom (Contributo in atti di convegno)

Type
Label
  • Vacuum facility for calibration of space instrumentation in cleanroom (Contributo in atti di convegno) (literal)
Anno
  • 2012-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1117/12.927294 (literal)
Alternative label
  • Pelizzo, Maria Guglielmina; Zuppella, Paola; Polito, Vanessa; Corso, Alain Jody; Zuccon, Sara; Nicolosi, Piergiorgio (2012)
    Vacuum facility for calibration of space instrumentation in cleanroom
    in SPIE Astronomical Telescopes + Instrumentation 2012
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Pelizzo, Maria Guglielmina; Zuppella, Paola; Polito, Vanessa; Corso, Alain Jody; Zuccon, Sara; Nicolosi, Piergiorgio (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.scopus.com/record/display.url?eid=2-s2.0-84871741761&origin=inward (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 8443 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#volumeInCollana
  • 8443 (literal)
Rivista
Note
  • Scopu (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Consiglio Nazionale delle Ricerche; Universita degli Studi di Padova (literal)
Titolo
  • Vacuum facility for calibration of space instrumentation in cleanroom (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 9780819491442 (literal)
Abstract
  • Calibration of optical systems is a fundamental step in the development of a space instrumentation. We have built a new cleanroom environment, divided in different areas characterized by a different level of contamination control. A vacuum chamber (a tube of 80 cm diameter, and 2 m length), able to accommodate optical components as well as whole instruments, is interfaced with a ISO6 area, allowing the handling of the instrumentation in a clean environment. The vacuum system is dimensioned to reach 10-7 mbar pressure in the chamber. Inside, a two axis platform allows the rotation of the instrument with respect to the incident collimating beam, in order to test the response of the instrument to light coming from different points of the field of view. A monochromator coupled with different sources provides radiation in the 40-350 nm spectral range, while a parabolic mirror is used as a collimator. As source, different spectral lamps can be used to generate emission lines, while a Xe lamp can be used to have continuum spectrum. An high brilliant hollow cathode lamp has been fabricated by the group to generate extreme ultraviolet radiation. Different calibrated detectors and other completing optical components are available. © 2012 SPIE. (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it