Pentafluorophenylhydrazine as Coating Reagent for the HRGC_MS Determination of Semi-Volatile Carbonyl Compounds in Air (Articolo in rivista)

Type
Label
  • Pentafluorophenylhydrazine as Coating Reagent for the HRGC_MS Determination of Semi-Volatile Carbonyl Compounds in Air (Articolo in rivista) (literal)
Anno
  • 2001-01-01T00:00:00+01:00 (literal)
Alternative label
  • Cecinato A., Di Palo V., Mabilia R., Possanzini M. (2001)
    Pentafluorophenylhydrazine as Coating Reagent for the HRGC_MS Determination of Semi-Volatile Carbonyl Compounds in Air
    in Chromatographia (Wiesb.)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Cecinato A., Di Palo V., Mabilia R., Possanzini M. (literal)
Pagina inizio
  • 263 (literal)
Pagina fine
  • 269 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 54 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#descrizioneSinteticaDelProdotto
  • Sensitive detection of semi-volatile carbonyl compounds in air can be achieved by using pentafluorophenylhydrazine-coated (PFPH) silica cartridges. Hydrazones formed during sampling are extracted with dichloromethane-acetonitrile and analysed by GC-MS operated in selected-ion-monitoring mode (SIM). The low detection limits reached (20 ppt (v/v) for sampling periods of 1 h) makes this method a valid alternative to other HPLC-UV and HRGC_MS techniques recently developed. Several experimental variables, for example collection and derivatization efficienty, interference by ozone, and storage stability of blank and sampled cartridges, have been investigated. Comparison field tests with the classical dinitrophenylhydrazine (DNPH) method showed results to be very consistentfor C4-C11 n-alkanals and 6-h sampling periods during which six PFPH cartridges were run in parallel (each for 1h)with one 2,4-dinitrophenylhydrazine(DNPH)-coated cartridge. (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1- CNR-IIA 2- CNR-IIA 3- CNR-IIA 4- CNR-IIA (literal)
Titolo
  • Pentafluorophenylhydrazine as Coating Reagent for the HRGC_MS Determination of Semi-Volatile Carbonyl Compounds in Air (literal)
Abstract
  • Sensitive detection of semi-volatile carbonyl compounds in air can be achieved by using pentafluorophenylhydrazine-coated (PFPH) silica cartridges. Hydrazones formed during sampling are extracted with dichloromethane-acetonitrile and analysed by GC-MS operated in selected-ion-monitoring mode (SIM). The low detection limits reached (20 ppt (v/v) for sampling periods of 1 h) makes this method a valid alternative to other HPLC-UV and HRGC_MS techniques recently developed. Several experimental variables, for example collection and derivatization efficienty, interference by ozone, and storage stability of blank and sampled cartridges, have been investigated. Comparison field tests with the classical dinitrophenylhydrazine (DNPH) method showed results to be very consistentfor C4-C11 n-alkanals and 6-h sampling periods during which six PFPH cartridges were run in parallel (each for 1h)with one 2,4-dinitrophenylhydrazine(DNPH)-coated cartridge. (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it