Micromachined gas calibration sources based on nanometric depth microchannels (Contributo in atti di convegno)

Type
Label
  • Micromachined gas calibration sources based on nanometric depth microchannels (Contributo in atti di convegno) (literal)
Anno
  • 2010-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.proeng.2010.09.363 (literal)
Alternative label
  • Zampolli, S.; Elmi, I.; Mancarella, F.; Messina, M.; Marra, G.; Cozzani, E.; Belluce, M.; Tamarri, F.; Sanmartin, M.; Cardinali, G. C.; Severi, M. (2010)
    Micromachined gas calibration sources based on nanometric depth microchannels
    in Eurosensor XXIV Conference, 2010
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Zampolli, S.; Elmi, I.; Mancarella, F.; Messina, M.; Marra, G.; Cozzani, E.; Belluce, M.; Tamarri, F.; Sanmartin, M.; Cardinali, G. C.; Severi, M. (literal)
Pagina inizio
  • 1344 (literal)
Pagina fine
  • 1347 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#volumeInCollana
  • 5 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 4 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Consiglio Nazionale delle Ricerche (CNR) (literal)
Titolo
  • Micromachined gas calibration sources based on nanometric depth microchannels (literal)
Abstract
  • In this work a MEMS gas calibration source will be presented. For reliable and quantitative automatic measures over long periods of time, gas sensors and micro-analytical-systems require periodical calibrations. The authors developed an innovative solution based on a liquid reservoir and silicon micromachined nanochannels. To provide low emission rates of highly volatile substances (e. g. toluene) in the ng/min range, micro-channels have millimetric length, micrometric width and nanometric depth, with a typical cross-section of 0.5 mu m(2). Prototypal devices with different channel dimensions, shapes and numbers have been built and functionally characterized. Technological fabrication process flow and characterization results will be shown, and the results will be compared with commercially available permeation tubes. (C) 2010 Published by Elsevier Ltd. (literal)