Optical diagnostics of streamers: from laboratory micro-scale to upper-atmospheric large-scale discharges (Articolo in rivista)

Type
Label
  • Optical diagnostics of streamers: from laboratory micro-scale to upper-atmospheric large-scale discharges (Articolo in rivista) (literal)
Anno
  • 2014-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1088/1742-6596/550/1/012037 (literal)
Alternative label
  • M Simek, T Hoder, V Prukner and P F Ambrico (2014)
    Optical diagnostics of streamers: from laboratory micro-scale to upper-atmospheric large-scale discharges
    in Journal of physics. Conference series (Print); IOP PUBLISHING, BRISTOL (Regno Unito)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • M Simek, T Hoder, V Prukner and P F Ambrico (literal)
Pagina inizio
  • 012037 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://iopscience.iop.org/1742-6596/550/1/012037 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 550 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 10 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 1 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopu (literal)
  • Google Scholar (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1 Institute of Plasma Physics, v.v.i., Academy of Sciences of the Czech Republic, Za Slovankou 3, 18200 Prague, Czech Republic 2 Leibniz Institute for Plasma Science and Technology, Felix/Hausdorff/Str 2, 17489 Greifswald, Germany 3 Istituto di Metodologie Inorganiche e dei Plasmi - CNR, Via Orabona 4, 70126 Bari, Italy (literal)
Titolo
  • Optical diagnostics of streamers: from laboratory micro-scale to upper-atmospheric large-scale discharges (literal)
Abstract
  • Optical emission produced by streamers is determined by spatial distribution of electronically excited atomic and diatomic species within the streamer head and streamer channel. Peculiarities of emission and LIF diagnostics dedicated to investigating the basic structure of streamers with high spatio-temporal resolution are discussed. Possible strategies based on the 2D projections of cylindrically symmetric streamers to determine radial distributions of excited species within the streamer channel are illustrated for streamers produced in volume or on the dielectric surface at atmospheric and low pressures. (literal)
Editore
Prodotto di
Autore CNR

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
data.CNR.it