http://www.cnr.it/ontology/cnr/individuo/prodotto/ID278018
An image filtering technique for SPIDER visible tomography (Articolo in rivista)
- Type
- Label
- An image filtering technique for SPIDER visible tomography (Articolo in rivista) (literal)
- Anno
- 2014-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1063/1.4850738 (literal)
- Alternative label
Fonnesu N.; Agostini M.; Brombin M.; Pasqualotto R.; Serianni G. (2014)
An image filtering technique for SPIDER visible tomography
in Review of scientific instruments; AMER INST PHYSICS, CIRCULATION & FULFILLMENT DIV, 2 HUNTINGTON QUADRANGLE, STE 1 N O 1, MELVILLE, NY 11747-4501 (Stati Uniti d'America)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Fonnesu N.; Agostini M.; Brombin M.; Pasqualotto R.; Serianni G. (literal)
- Pagina inizio
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- Article number: 4850738 / Contributed paper, published as part of the Proceedings of the 15th International Conference on Ion Sources, Chiba, Japan, September 2013.
Review of scientific instruments online
Editore: American Institute of Physics
Paese di pubblicazione: Stati Uniti d'America
Lingua: inglese
e-Issn: 1089-7623
Titolo chiave: Review of scientific instruments online
Titolo proprio: Review of scientific instruments online
Titolo abbreviato: Rev. sci. instrum. online (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://scitation.aip.org/content/aip/journal/rsi/85/2/10.1063/1.4850738 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Scopu (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova, Italy (literal)
- Titolo
- An image filtering technique for SPIDER visible tomography (literal)
- Abstract
- The tomographic diagnostic developed for the beam generated in the SPIDER facility (100 keV, 50 A prototype negative ion source of ITER neutral beam injector) will characterize the two-dimensional particle density distribution of the beam. The simulations described in the paper show that instrumental noise has a large influence on the maximum achievable resolution of the diagnostic. To reduce its impact on beam pattern reconstruction, a filtering technique has been adapted and implemented in the tomography code. This technique is applied to the simulated tomographic reconstruction of the SPIDER beam, and the main results are reported. (literal)
- Editore
- Prodotto di
- Autore CNR
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di