http://www.cnr.it/ontology/cnr/individuo/prodotto/ID275307
Detecting ionizing radiation with optical fibers down to biomedical doses (Articolo in rivista)
- Type
- Label
- Detecting ionizing radiation with optical fibers down to biomedical doses (Articolo in rivista) (literal)
- Anno
- 2013-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1063/1.4826934 (literal)
- Alternative label
Avino, S., D'Avino, V., Giorgini, A., Pacelli, R., Liuzzi, R., Cella, L., De Natale, P., Gagliardi, G. (2013)
Detecting ionizing radiation with optical fibers down to biomedical doses
in Applied physics letters
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Avino, S., D'Avino, V., Giorgini, A., Pacelli, R., Liuzzi, R., Cella, L., De Natale, P., Gagliardi, G. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Scopu (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- a Consiglio Nazionale Delle Ricerche, Istituto Nazionale di Ottica (INO), via Campi Flegrei, 34, Comprensorio A. Olivetti, Pozzuoli (Naples) 80078, Italy
b Consiglio Nazionale Delle Ricerche, Istituto di Biostrutture e Bioimmagini, via Tommaso De Amicis 95, 80131 Napoli, Italy
c Dipartimento di Scienze Biomediche Avanzate, Università di Napoli Federico II, via Pansini 5, 80131 Napoli, Italy (literal)
- Titolo
- Detecting ionizing radiation with optical fibers down to biomedical doses (literal)
- Abstract
- We report on a passive ionizing radiation sensor based on a fiber-optic resonant cavity interrogated by a high resolution interferometric technique. After irradiation in clinical linear accelerators, we observe significant variations of the fiber thermo-optic coefficient. Exploiting this effect, we demonstrate an ultimate detection limit of 160 mGy with an interaction volume of only 6?10?4 mm3.
Thanks to its reliability, compactness, and sensitivity at biomedical dose levels, our system lends itself to real applications in radiation therapy procedures as well as in radiation monitoring and protection in medicine, aerospace, and nuclear power plants (literal)
- Prodotto di
- Autore CNR
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi