High resolution soft x-ray tomography in the Madison Symmetric Torus (Articolo in rivista)

Type
Label
  • High resolution soft x-ray tomography in the Madison Symmetric Torus (Articolo in rivista) (literal)
Anno
  • 2004-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.1794845 (literal)
Alternative label
  • Franz P.; F.Bonomo; G.Gadani; L.Marrelli; P.Martin; P.Piovesan; G.Spizzo; B.E.Chapman; M.Reyfman (2004)
    High resolution soft x-ray tomography in the Madison Symmetric Torus
    in Review of scientific instruments
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Franz P.; F.Bonomo; G.Gadani; L.Marrelli; P.Martin; P.Piovesan; G.Spizzo; B.E.Chapman; M.Reyfman (literal)
Pagina inizio
  • 4013 (literal)
Pagina fine
  • 4016 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • PROCEEDINGS OF THE 15TH TOPICAL CONFERENCE ON HIGH-TEMPERATURE PLASMA DIAGNOSTICS / MICROWAVES, REFLECTOMETRY, ECE, THOMSON (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://rsi.aip.org/resource/1/rsinak/v75/i10/p4013_s1?isAuthorized=no (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 75 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 4 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 10 (literal)
Note
  • Scopu (literal)
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Franz P.; F.Bonomo; G.Gadani; L.Marrelli; P.Martin; P.Piovesan; G.Spizzo: Consorzio RFX-Associazione EURATOM ENEA sulla fusione, Padova, Italy / B.E.Chapman; M.Reyfman: MST Group, Physics Department, University of Wisconsin, Madison, Wisconsin 53706 (literal)
Titolo
  • High resolution soft x-ray tomography in the Madison Symmetric Torus (literal)
Abstract
  • We present in this article the description of the upgraded soft x-ray tomographic diagnostic which has been installed in the Madison symmetric torus (MST) reversed field pinch. The previous diagnostic has been extended with two manipulators, for a total of three moveable probes and a fixed one. The line integrated emissivity (brightness) will be measured with arrays of photodiodes and the total number of channels has been increased from 24 to 74. The electronic layout has also been upgraded, and a type of custom made current-to-voltage amplifier has been developed. The diagnostic will be used to continue and extend the magnetohydrodynamics analysis of the MST plasma. The imaging of rotating coherent structures (one or, as recently showed, two) which appear during quasisingle helicity or pulsed poloidal current drive experiments will be performed in more detail. The photocameras can be easily extracted, modified, and inserted again, allowing applications and utilizations of the diagnostic. © 2004 American Institute of Physics. (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Prodotto
Autore CNR di
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Insieme di parole chiave di
data.CNR.it