http://www.cnr.it/ontology/cnr/individuo/prodotto/ID26166
High resolution soft x-ray tomography in the Madison Symmetric Torus (Articolo in rivista)
- Type
- Label
- High resolution soft x-ray tomography in the Madison Symmetric Torus (Articolo in rivista) (literal)
- Anno
- 2004-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1063/1.1794845 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Franz P.; F.Bonomo; G.Gadani; L.Marrelli; P.Martin; P.Piovesan; G.Spizzo; B.E.Chapman; M.Reyfman (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- PROCEEDINGS OF THE 15TH TOPICAL CONFERENCE ON HIGH-TEMPERATURE PLASMA DIAGNOSTICS / MICROWAVES, REFLECTOMETRY, ECE, THOMSON (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://rsi.aip.org/resource/1/rsinak/v75/i10/p4013_s1?isAuthorized=no (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- Scopu (literal)
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Franz P.; F.Bonomo; G.Gadani; L.Marrelli; P.Martin; P.Piovesan; G.Spizzo: Consorzio RFX-Associazione EURATOM ENEA sulla fusione, Padova, Italy /
B.E.Chapman; M.Reyfman: MST Group, Physics Department, University of Wisconsin, Madison, Wisconsin 53706 (literal)
- Titolo
- High resolution soft x-ray tomography in the Madison Symmetric Torus (literal)
- Abstract
- We present in this article the description of the upgraded soft x-ray tomographic diagnostic which
has been installed in the Madison symmetric torus (MST) reversed field pinch. The previous
diagnostic has been extended with two manipulators, for a total of three moveable probes and a fixed
one. The line integrated emissivity (brightness) will be measured with arrays of photodiodes and the
total number of channels has been increased from 24 to 74. The electronic layout has also been
upgraded, and a type of custom made current-to-voltage amplifier has been developed. The
diagnostic will be used to continue and extend the magnetohydrodynamics analysis of the MST
plasma. The imaging of rotating coherent structures (one or, as recently showed, two) which appear
during quasisingle helicity or pulsed poloidal current drive experiments will be performed in more
detail. The photocameras can be easily extracted, modified, and inserted again, allowing applications
and utilizations of the diagnostic. © 2004 American Institute of Physics. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di