http://www.cnr.it/ontology/cnr/individuo/prodotto/ID26109
Ionizing radiation compatibility in the MITICA neutral beam prototype (Articolo in rivista)
- Type
- Label
- Ionizing radiation compatibility in the MITICA neutral beam prototype (Articolo in rivista) (literal)
- Anno
- 2011-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.fusengdes.2011.02.021 (literal)
- Alternative label
M. Bagatin; A. Coniglio; M. D'Arienzo; A. De Lorenzi; S. Gerardin; A. Paccagnella; R. Pasqualotto; S. Peruzzo; S. Sandri; B. Zaniol (2011)
Ionizing radiation compatibility in the MITICA neutral beam prototype
in Fusion engineering and design; ELSEVIER SCIENCE SA, PO BOX 564, 1001 LAUSANNE (Svizzera)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- M. Bagatin; A. Coniglio; M. D'Arienzo; A. De Lorenzi; S. Gerardin; A. Paccagnella; R. Pasqualotto; S. Peruzzo; S. Sandri; B. Zaniol (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- La rivista è pubblicata anche online con ISSN 1873-7196 (Editore: Elsevier Science SA) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://www.sciencedirect.com/science/article/pii/S0920379611001797 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- Scopu (literal)
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- a. DEI, Università di Padova, Via Gradenigo 6B, I-35131 Padova, Italy;
b. Ospedale Fatebenefratelli, Isola Tiberina, Roma, Italy;
c. Consorzio RFX - Association EURATOM-ENEA, C.so Stati Uniti 4, 35127 Padova, Italy;
d. ENEA, Radiation Protection Institute, Via E. Fermi, 45, I-00044 Frascati, Italy.
(M. Bagatin a , A. Coniglio b , M. D'Arienzo c , A. De Lorenzi c , S. Gerardin a , A. Paccagnella a , R. Pasqualotto c , S. Peruzzo c , S. Sandri d , B. Zaniol c) (literal)
- Titolo
- Ionizing radiation compatibility in the MITICA neutral beam prototype (literal)
- Abstract
- This paper deals with an R&D activity in progress in support of the design of the ITER NBI prototype (MITICA), aimed at the identification of the most appropriate design solutions and installation guidelines to keep under control and minimize the effects of ionizing radiation on the electronic and passive components related to control, diagnostics, and electrical insulation located inside the MITICA vessel and its concrete biological shield. The method followed to approach the problem is based on three steps: estimation of expected radiation levels map, identification of electronic and passive components database for MITICA diagnostics and finally the assessment of the ionizing radiation compatibility for the identified components. The ultimate aim of this activity is the definition, on the basis of this assessment, of a list of preventive or mitigating actions (such as relocation, shielding or preventive maintenance) for the most high-risk components. (literal)