Three-dimensional spin nanosensor based on reliable tunnel Josephson nano-junctions for nanomagnetism investigations (Articolo in rivista)

Type
Label
  • Three-dimensional spin nanosensor based on reliable tunnel Josephson nano-junctions for nanomagnetism investigations (Articolo in rivista) (literal)
Anno
  • 2013-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.4819463 (literal)
Alternative label
  • Granata, Carmine; Vettoliere, Antonio; Russo, Roberto; Fretto, Matteo; De Leo, Natascia; Lacquaniti, Vincenzo (2013)
    Three-dimensional spin nanosensor based on reliable tunnel Josephson nano-junctions for nanomagnetism investigations
    in Applied physics letters; AIP Publishing LLC, Melville, NY 11747 (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Granata, Carmine; Vettoliere, Antonio; Russo, Roberto; Fretto, Matteo; De Leo, Natascia; Lacquaniti, Vincenzo (literal)
Pagina inizio
  • 102602-1 (literal)
Pagina fine
  • 102602-5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 103 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 10 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Consiglio Nazionale delle Ricerche (CNR); Ist Nazl Ric Metrol (literal)
Titolo
  • Three-dimensional spin nanosensor based on reliable tunnel Josephson nano-junctions for nanomagnetism investigations (literal)
Abstract
  • We present an ultra high sensitive three-dimensional nano Superconducting QUantum Interference Device (nanoSQUID) fabricated by using the Focused Ion Beam sculpting technique. Based on a fully niobium technology, the nanodevice consists in a niobium superconducting loop (0.2 mu m(2)) interrupted by two nanometric Nb/Al-AlOx/Nb Josephson junctions. The nanoSQUID exhibited an intrinsic magnetic flux noise as low as 0.65 mu Phi(0)/Hz(1/2) corresponding to a spin noise less than 10 Bohr magnetons per unit of bandwidth. It has been successfully employed in nanoparticle magnetic relaxation measurements. Due to its excellent performance, reliability, and robustness, we believe that the proposed nanoSQUID offers a crucial step toward a wide employment of nanoSQUIDs in the nanoscience. (C) 2013 AIP Publishing LLC. (literal)