http://www.cnr.it/ontology/cnr/individuo/prodotto/ID253355
Analysis of poly(bisphenol A carbonate) by size exclusion chromatography/matrix-assisted laser desorption/ioinization. 1. End group and molar mass determination (Articolo in rivista)
- Type
- Label
- Analysis of poly(bisphenol A carbonate) by size exclusion chromatography/matrix-assisted laser desorption/ioinization. 1. End group and molar mass determination (Articolo in rivista) (literal)
- Anno
- 1999-01-01T00:00:00+01:00 (literal)
- Alternative label
Concetto Puglisi, Filippo Samperi, Sabrina Carroccio and Giorgio Montaudo (1999)
Analysis of poly(bisphenol A carbonate) by size exclusion chromatography/matrix-assisted laser desorption/ioinization. 1. End group and molar mass determination
in RCM. Rapid communications in mass spectrometry
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Concetto Puglisi, Filippo Samperi, Sabrina Carroccio and Giorgio Montaudo (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- CNR; Università Catania (literal)
- Titolo
- Analysis of poly(bisphenol A carbonate) by size exclusion chromatography/matrix-assisted laser desorption/ioinization. 1. End group and molar mass determination (literal)
- Abstract
- The determination of molar mass (MM) data for polydisperse polymers by SEC/MALDI involves the
fractionation of samples through analytical size exclusion chromatography (SEC). Selected SEC fractions
are then analyzed by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and the mass
spectra of these nearly monodisperse samples allow the determination of the average molar masses. The
SEC/MALDI procedure has now been applied to two polycarbonate samples, PC1 and PC2. The results
show that the MALDI spectra of the SEC fractions allow not only the detection of linear and cyclic
oligomers contained in these samples, but also the simultaneous determination of their average molar
masses. Two slightly differing SEC calibration plots were obtained, due to the smaller hydrodynamic
volume of the polycarbonate cyclic chains with respect to the linear ones. In agreement with theory, the ratio
(Mcycle/Mlinear)Ve at a fixed elution volume was found to be 1.22, independent of the molar mass values. (literal)
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di