High power system for ECRH at 140Ghz, 2MW, 0.5s on FTU tokamak (Contributo in atti di convegno)

Type
Label
  • High power system for ECRH at 140Ghz, 2MW, 0.5s on FTU tokamak (Contributo in atti di convegno) (literal)
Anno
  • 1999-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.59709 (literal)
Alternative label
  • Sozzi, C; Berardi, B; Bozzi, R; Bruschi, A; Ciccone, G; Cirant, S; DiGiovenale, S; Gandini, F; Granucci, G; Iannone, F; Lupini, S; Mantovani, S; Mellera, V; Muzzini, V; Nardone, A; Pesci, E; Simonetto, A; Spinicchia, N (1999)
    High power system for ECRH at 140Ghz, 2MW, 0.5s on FTU tokamak
    in 13th Topical Conference on Radio Frequency Power in Plasmas, ANNAPOLIS, MD, APR 12-14, 1999
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Sozzi, C; Berardi, B; Bozzi, R; Bruschi, A; Ciccone, G; Cirant, S; DiGiovenale, S; Gandini, F; Granucci, G; Iannone, F; Lupini, S; Mantovani, S; Mellera, V; Muzzini, V; Nardone, A; Pesci, E; Simonetto, A; Spinicchia, N (literal)
Pagina inizio
  • 462 (literal)
Pagina fine
  • 465 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://proceedings.aip.org/resource/2/apcpcs/485/1/462_1 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
  • RADIO FREQUENCY POWER IN PLASMAS (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#volumeInCollana
  • 485 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 4 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • IFP-CNR Milano Italy ENEA Frascati Italy (literal)
Titolo
  • High power system for ECRH at 140Ghz, 2MW, 0.5s on FTU tokamak (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 1-56396-861-4 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#curatoriVolume
  • Bernabei, S; Paoletti, F (literal)
Abstract
  • The 140GHz, 2MW, 0.5s ECRH system on FTU tokamak integrates closed waveguide transmission lines (-30 m) with quasi optical systems at both ends for efficient coupling from the 4 gyrotrons to the 4 waveguides and from these to the plasma through a single access port. Poloidal and toroidal control of the beam's launching angles and polarisation is performed without movable components close to the plasma Most of the components of each generation and transmission system were designed to operate at a power level higher than 0.5 MW and a possible up-grade to a full 1 MW, 0.5 s capability is discussed. (literal)