RFX diagnostics (Articolo in rivista)

Type
Label
  • RFX diagnostics (Articolo in rivista) (literal)
Anno
  • 1995-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/0920-3796(94)00283-D (literal)
Alternative label
  • M. Bagatin; A. Buffa; V. Antoni; M. Bassan; L. Carraro; S. Costa; D. Desideri; G. Gadani; L. Giudicotti; P. Innocente; P. Martin; S. Martini; M. Monari; M. Moresco; A. Murari; A. Parini; R. Pasqualotto; M. E. Puiatti; A. Sardella; P. Scarin; M. Valisa; E. Zilli (1995)
    RFX diagnostics
    in Fusion engineering and design; Elsevier, Amsterdam (Paesi Bassi)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • M. Bagatin; A. Buffa; V. Antoni; M. Bassan; L. Carraro; S. Costa; D. Desideri; G. Gadani; L. Giudicotti; P. Innocente; P. Martin; S. Martini; M. Monari; M. Moresco; A. Murari; A. Parini; R. Pasqualotto; M. E. Puiatti; A. Sardella; P. Scarin; M. Valisa; E. Zilli (literal)
Pagina inizio
  • 425 (literal)
Pagina fine
  • 460 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • 36 pages paper / E-ISSN: 1873-7196 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.sciencedirect.com/science/article/pii/092037969400283D (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 25 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 36 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 4 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopu (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Gruppo di Padova per Ricerche sulla Fusione, AssociazioniEURATOM-ENEA-CNR-Universita' di Padova, Sede: IstitutoGaslonizzati-CNR, Corso Stati Uniti 4, 35020 Padova, Italy (literal)
Titolo
  • RFX diagnostics (literal)
Abstract
  • In this paper the diagnostic systems implemented on the reversed field pinch (RFP) experiment RFX are presented. The paper is mainly concerned with the general engineering aspects and with the development work addressed to meet specific requirements such as immunity to electrical noise, ultrahigh vacuum compatibility, reliability. A general guideline adopted in the development of diagnostics was to use, whenever possible, proven methods, at least for the systems dedicated to the measurement of the most significant parameters. Each section of the paper illustrates a different system, in which the diagnostic constraints and the specific choices derived from the peculiarities of the RFP configuration are discussed. Although the majority of the diagnostic instruments are at present fully developed and operational, some of them, i.e. far-IR polarimeter, microwave reflectometer, soft X-ray and bolometer tomographic system are either under prototype testing or under construction. (literal)