Thymol blue immobilized on tapered fibres as an optical transducer for pH sensing (Contributo in atti di convegno)

Type
Label
  • Thymol blue immobilized on tapered fibres as an optical transducer for pH sensing (Contributo in atti di convegno) (literal)
Anno
  • 1999-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1117/12.339805 (literal)
Alternative label
  • F.Baldini, L.Ciaccheri, A.Falai, A.G.Mignani, J.Rayss, G.Sudolski (1999)
    Thymol blue immobilized on tapered fibres as an optical transducer for pH sensing
    in Chemical, Biochemical and Environmental Fiber Sensors X, Boston, 2-5 Novembre 1998
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • F.Baldini, L.Ciaccheri, A.Falai, A.G.Mignani, J.Rayss, G.Sudolski (literal)
Pagina inizio
  • 28 (literal)
Pagina fine
  • 33 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://scholar.google.it/citations?view_op=view_citation&hl=it&user=gcrCP00AAAAJ&cstart=100&pagesize=100&sortby=pubdate&citation_for_view=gcrCP00AAAAJ:dQ2og3OwTAUC (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
  • Chemical, Biochemical and Environmental Fiber Sensors X (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#volumeInCollana
  • 3540 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 6 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Google S (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Istituto di Ricerca sulle Onde Elettromagnetiche - IROE-CNR, Firenze,Italy Maria Curie-Sklodowska University, Faculty of Chemistry, Lublin, Poland (literal)
Titolo
  • Thymol blue immobilized on tapered fibres as an optical transducer for pH sensing (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 0-8194-3001-3 (literal)
Abstract
  • The present work is concerned with the optical characterization of an evanescent wave sensor for pH detection. First, the interaction between the solution containing the acid-base indicator and the fibre core was investigated. Then, the acid-base indicator, thymol blue, was covalently immobilized on the core of a 200/380 itm fibre by means of a silylation process of the glass surface. The fibre core surface was modified along a section of 8 mm. A comparison was made using both bare and tapered fibres, with a tapering ratio (fibre diameter/waist diameter) of 2.3. An enhancement in sensitivity of a factor 6 was observed with tapered fibres in thel÷2.5 range, and a sensitivity of 0.05 pH units was attained. (literal)
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Autore CNR di
Prodotto
Insieme di parole chiave di
data.CNR.it