An inexpensive instrument to detect radio-frequency leakage from transmission lines at millimeter wavelengths for personnel safety (Articolo in rivista)

Type
Label
  • An inexpensive instrument to detect radio-frequency leakage from transmission lines at millimeter wavelengths for personnel safety (Articolo in rivista) (literal)
Anno
  • 1996-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.1147581 (literal)
Alternative label
  • Simonetto, A; Muzzini, V; Bruschi, A; Cirant, S; Granucci, G; Sozzi, C (1996)
    An inexpensive instrument to detect radio-frequency leakage from transmission lines at millimeter wavelengths for personnel safety
    in Review of scientific instruments; AIP, American institute of physics, Melville, NY (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Simonetto, A; Muzzini, V; Bruschi, A; Cirant, S; Granucci, G; Sozzi, C (literal)
Pagina inizio
  • 4333 (literal)
Pagina fine
  • 4335 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://rsi.aip.org/resource/1/rsinak/v67/i12/p4333_s1 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 67 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 3 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 12 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR sulla Fusione, Via Bassini 15, 20133 Milano, Italy (literal)
Titolo
  • An inexpensive instrument to detect radio-frequency leakage from transmission lines at millimeter wavelengths for personnel safety (literal)
Abstract
  • Arrays of thermopile detectors arranged on flat panels were used to measure stray radiation from high-power transmission lines at 140 GHz in the FTU tokamak electron cyclotron resonance heating experiment. These instruments are insensitive to polarization and to the direction of propagation within +/-40 degrees off normal incidence. They have a time constant of 120 ms, therefore amplification and synchronous detection are required for the measurement of short radiation pulses. No special measurement techniques are required with long pulses or cw radiation. The typical sensitivity is 2 mV cm(2)/mW in long pulse operation and 47 mu V cm(2)/mW for 1 ms pulses. The detectors are sensitive to light and adequate filtering should be added to suppress it if necessary. These characteristics are adequate for the measurement of human exposure levels to electromagnetic radiation in the millimeter wave range. (C) 1996 American Institute of Physics. (literal)