Design and characterisation of black-body sources for infrared wide-band Fourier transform spectroscopy (Articolo in rivista)

Type
Label
  • Design and characterisation of black-body sources for infrared wide-band Fourier transform spectroscopy (Articolo in rivista) (literal)
Anno
  • 2008-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1016/j.infrared.2007.06.001 (literal)
Alternative label
  • L. Palchetti, G. Bianchini, F. Castagnoli (2008)
    Design and characterisation of black-body sources for infrared wide-band Fourier transform spectroscopy
    in Infrared physics & technology
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • L. Palchetti, G. Bianchini, F. Castagnoli (literal)
Pagina inizio
  • 207 (literal)
Pagina fine
  • 215 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.sciencedirect.com/science/article/pii/S1350449507000709 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 51 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 9 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 3 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • IFAC - Istituto di fisica applicata \"Nello Carrara\" - CNR (literal)
Titolo
  • Design and characterisation of black-body sources for infrared wide-band Fourier transform spectroscopy (literal)
Abstract
  • The design and characterisation of small and cost-effective reference black-body sources for radiometric calibration of Fourier transform spectrometers in the mid and far infrared is presented. The paper describes the optimisation of the absorbing black-coating material and the study of two types of cavity geometry, one designed for collimated beams and one for focused beams. These two reference sources have been developed for the Radiation Explorer in the Far InfraRed spectrometer covering the 100-1400 cm(-1) spectral range. They are currently used on-board two prototypes for ground and stratospheric balloon based atmospheric emission measurements. An emissivity of better than 0.9999 is obtained for both type of cavity geometry giving a calibration error, depending only on the temperature gradient inside the blackbody, of less than 0.5 K (literal)