http://www.cnr.it/ontology/cnr/individuo/prodotto/ID22686
Infrared balloon experiment: improved instrumental configuration and assessment of instrument performance (Articolo in rivista)
- Type
- Label
- Infrared balloon experiment: improved instrumental configuration and assessment of instrument performance (Articolo in rivista) (literal)
- Anno
- 2006-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1364/AO.45.001041 (literal)
- Alternative label
G.Bianchini (1), A.Boscaleri (1), B. Carli (1), F.Mencaraglia, L.Palchetti (1), E.Pascale (2) (2006)
Infrared balloon experiment: improved instrumental configuration and assessment of instrument performance
in Applied optics; Optical Society of America, Washington (Stati Uniti d'America)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- G.Bianchini (1), A.Boscaleri (1), B. Carli (1), F.Mencaraglia, L.Palchetti (1), E.Pascale (2) (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://www.opticsinfobase.org/ao/abstract.cfm?uri=AO-45-5-1041 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- 1) Istituto di Fisica Applicata \"Nello Carrara\" - Consiglio Nazionale delle Ricerche (IFAC-CNR), Sesto Fiorentino, Firenze, I-50019, Italy
2) University of Toronto (literal)
- Titolo
- Infrared balloon experiment: improved instrumental configuration and assessment of instrument performance (literal)
- Abstract
- During the 2002 environmental satellite Envisat mid-latitude validation campaign, a new upgraded configuration of the Infrared Balloon Experiment (IBEX) Fourier transform spectrometer, which had its first flight in 1978, performed a stratospheric balloon flight across the Mediterranean Sea. Among the substantial upgrades made to the instrument, the use of photon-noise-limited detectors permitted us to reach the theoretical limits in terms of signal-to-noise ratio. Also, important modifications were made to the interferometric system and electronics, such as the installation of a solid-state laser reference source and an onboard data recording system. During the flight, measurement of volume-mixing-ratio vertical profiles of O3, HNO3, N2O, and ClO from an altitude of 38 km were performed with a vertical resolution of 1.5 km. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di