ABSOLUTE CALIBRATION OF A VACUUM CZERNY-TURNER SPECTROMETER IN THE RANGE 1200-7000-ANGSTROM (Articolo in rivista)

Type
Label
  • ABSOLUTE CALIBRATION OF A VACUUM CZERNY-TURNER SPECTROMETER IN THE RANGE 1200-7000-ANGSTROM (Articolo in rivista) (literal)
Anno
  • 1995-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.1146303 (literal)
Alternative label
  • CARRARO, L ; CORTIANA, M ; PUIATTI, ME ; SATTIN, F ; SCARIN, P; VALISA, M (1995)
    ABSOLUTE CALIBRATION OF A VACUUM CZERNY-TURNER SPECTROMETER IN THE RANGE 1200-7000-ANGSTROM
    in Review of scientific instruments; AMER INST PHYSICS, CIRCULATION FULFILLMENT DIV, 500 SUNNYSIDE BLVD, WOODBURY, NY 11797-2999 (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • CARRARO, L ; CORTIANA, M ; PUIATTI, ME ; SATTIN, F ; SCARIN, P; VALISA, M (literal)
Pagina inizio
  • 613 (literal)
Pagina fine
  • 615 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • E-ISSN: 1089-7623 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://scitation.aip.org/content/aip/journal/rsi/66/1/10.1063/1.1146303 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 66 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 3 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 1 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Istituto Gas Ionizzati del CNR, Euratom-ENEA-CNR Association Corso Stati Uniti, 4-35020 Padova, Italy (literal)
Titolo
  • ABSOLUTE CALIBRATION OF A VACUUM CZERNY-TURNER SPECTROMETER IN THE RANGE 1200-7000-ANGSTROM (literal)
Abstract
  • The vacuum Czerny-Turner high-resolution spectrometer observing the plasma of the reversed-field-pinch device RFX has been absolutely calibrated in the spectral range 1215-7000 Å, in order to measure the emission spectrum in absolute units, with particular reference to the heliumlike carbon and oxygen ion lines. The source used to calibrate the spectrometer in the vacuum and near-ultraviolet region is a deuterium lamp; its spectral radiance was determined by comparison with the synchrotron radiation of the electron storage ring BESSY, in Berlin. A typical error of 35% has been estimated. In the visible a standard tungsten lamp has been used. The calibration has been transferred to an ultragrazing incidence XUV spectrometer by means of the branching-ratio technique, using the intensity ratio between the intercombination 1s2 1S-1s2p 3P0 and the 1s2s 3S-1s2p 3P0 transitions of carbon, nitrogen, and oxygen heliumlike ions. (literal)