http://www.cnr.it/ontology/cnr/individuo/prodotto/ID22185
2D sot volume fraction imaging in an ethylene diffusion flame by two-color laser-induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics (Articolo in rivista)
- Type
- Label
- 2D sot volume fraction imaging in an ethylene diffusion flame by two-color laser-induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics (Articolo in rivista) (literal)
- Anno
- 2007-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/j.proci.2006.07.149 (literal)
- Alternative label
De Iuliis S., Migliorini F., Cignoli F., Zizak G. (2007)
2D sot volume fraction imaging in an ethylene diffusion flame by two-color laser-induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics
in Proceedings of the Combustion Institute
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- De Iuliis S., Migliorini F., Cignoli F., Zizak G. (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Titolo
- 2D sot volume fraction imaging in an ethylene diffusion flame by two-color laser-induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics (literal)
- Abstract
- The two-color laser-induced incandescence (2C-LII) technique can be used for soot volume fraction
measurements with no use of a reference flame of known soot concentration. In this work we have exploited
the 2C-LII technique with the development of a two-dimensional imaging arrangement. By utilizing an
IR pulsed laser, a laser sheet with sharp edges, and controlled fluence, the maximum soot temperature was
verified to be around 4000 K in all the investigated regions of an ethylene diffusion flame. The calibrationfree
2D 2C-LII arrangement was then feasible and applied for soot imaging. Verification of the soot volume
fraction measurements was carried out by comparison with other techniques such as ''point'' 2C-LII,
laser extinction, 2D extinction, and 2D two-color emission techniques. Agreements and some discrepancies
are discussed. (literal)