http://www.cnr.it/ontology/cnr/individuo/prodotto/ID221442
THE X-RAY-DIFFRACTION STATION AT THE ADONE WIGGLER FACILITY - PRELIMINARY-RESULTS (INCLUDING CRYSTAL PERFECTION) (Articolo in rivista)
- Type
- Label
- THE X-RAY-DIFFRACTION STATION AT THE ADONE WIGGLER FACILITY - PRELIMINARY-RESULTS (INCLUDING CRYSTAL PERFECTION) (Articolo in rivista) (literal)
- Anno
- 1992-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1107/S0021889891011445 (literal)
- Alternative label
COLAPIETRO, M; CAPPUCCIO, G; MARCIANTE, C; PIFFERI, A; SPAGNA, R; HELLIWELL, JR (1992)
THE X-RAY-DIFFRACTION STATION AT THE ADONE WIGGLER FACILITY - PRELIMINARY-RESULTS (INCLUDING CRYSTAL PERFECTION)
in Journal of applied crystallography; Munksgaard, Copenhagen (Danimarca)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- COLAPIETRO, M; CAPPUCCIO, G; MARCIANTE, C; PIFFERI, A; SPAGNA, R; HELLIWELL, JR (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- [ 1 ] CNR,IST STRUTT CHIM,I-00016 MONTEROTONDO,ITALY
[ 2 ] UNIV MANCHESTER,DEPT CHEM,MANCHESTER M13 9PL,LANCS,ENGLAND
[ 3 ] SERC,DARESBURY LAB,WARRINGTON WA4 4AD,CHESHIRE,ENGLAND (literal)
- Titolo
- THE X-RAY-DIFFRACTION STATION AT THE ADONE WIGGLER FACILITY - PRELIMINARY-RESULTS (INCLUDING CRYSTAL PERFECTION) (literal)
- Abstract
- The single-crystal X-ray diffractometer installed at the PWA Laboratory in Frascati is described. The Huber four-circle goniometer is controlled by an IBM-compatible personal computer by means of a plug-in board interface based on the LSI chip Am9513. The program CS running under MS-DOS performs a wide variety of operations from random search to data collection. The angular resolution of the diffractometer is 0.0025-degrees, while the instrumental resolution at 8 keV, with an Si(111) monochromator, is 0.0026-degrees. After preliminary tests. 2Zn insulin crystals were mounted on the diffractometer and reflections were measured using synchrotron radiation. The rocking curves show full widths at half-maxima (FWHM) in the range 0.013-0.031-degrees mainly due to the mosaicity. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Editore di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di