http://www.cnr.it/ontology/cnr/individuo/prodotto/ID216937
The tomographic diagnostic of ITER neutral beam injector (Articolo in rivista)
- Type
- Label
- The tomographic diagnostic of ITER neutral beam injector (Articolo in rivista) (literal)
- Anno
- 2013-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1088/0029-5515/53/5/053009 (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- M. Brombin; M. Agostini; C. Dianin; M. Mattiolo; R. Pasqualotto; G. Serianni; G. Spizzo (literal)
- Pagina inizio
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- Article Number: 053009.
La rivista è pubblicata anche online con ISSN 1741-4326. (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://iopscience.iop.org/0029-5515/53/5/053009/ (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Scopu (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- Consorzio RFX, Associazione EURATOM-ENEA sulla fusione, Corso Stati Uniti 4, Padova,Italy (literal)
- Titolo
- The tomographic diagnostic of ITER neutral beam injector (literal)
- Abstract
- The two-dimensional (2D) density distribution of a particle beam can be reconstructed using a diagnostic based on tomographic techniques, which measures the D? light. This paper presents investigations and tests concerning the reliability of such a diagnostic, applied to the beam produced in MITICA (Megavolt ITER Injector & Concept Advancement) the full-size prototype of the neutral beam injector, which will be used for additional heating on ITER. It aims at developing the technologies to guarantee the correct operation of the injectors to be installed in ITER. The main target of the tomographic diagnostic is the measurement of the beam uniformity with sufficient contrast and spatial resolution, and of its evolution throughout the pulse duration. In particular the ITER beam uniformity is required to be within 10%, thus the error of the tomographic reconstruction has to be lower than this value. The conceptual design of the diagnostic is presented, with a description of the layout and main components. The portholes around the vessel and the geometry of the lines of sight are arranged so as to cover the whole area of the beam. A tomographic algorithm based on the simultaneous algebraic reconstruction technique (SART) is developed to reconstruct the beam intensity profile. Phantoms reproducing different experimental beam configurations are simulated and reconstructed with this technique. The role of noise in the line-integrated signals is studied and its effect on the reconstructed emission is investigated. The unsatisfactory results suggested the introduction of a regularization algorithm, to reduce the effect of the noise in the beam reconstruction. In this way, the simulated phantoms are correctly reconstructed and their 2D spatial non-uniformity is correctly estimated, up to a noise level of 10%. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Autore CNR di
- Prodotto
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di