http://www.cnr.it/ontology/cnr/individuo/prodotto/ID215449
Organometallic polymer membrane for gas detection applied to a surface acoustic wave sensor (Articolo in rivista)
- Type
- Label
- Organometallic polymer membrane for gas detection applied to a surface acoustic wave sensor (Articolo in rivista) (literal)
- Anno
- 1995-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1016/0925-4005(95)85148-8 (literal)
- Alternative label
Cinzia Caliendo*, Enrico Verona*, Arnaldo D'Amico**, Anita Furlani***, Guido Infante***,
Maria Vittoria Russo*** (1995)
Organometallic polymer membrane for gas detection applied to a surface acoustic wave sensor
in Sensors and actuators. B, Chemical (Print); Elsevier, Amsterdam (Paesi Bassi)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Cinzia Caliendo*, Enrico Verona*, Arnaldo D'Amico**, Anita Furlani***, Guido Infante***,
Maria Vittoria Russo*** (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
- IDS Number: RN870
ISSN: 0925-4005 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://www.sciencedirect.com/science/article/pii/0925400595851488 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Scopu (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- *Istituto di Acustica O.M. Corbino, CNR, via Cassia 1216, I-00187 Rome, Italy
**Istituto di Elettronica, Universita`di Roma Tor Vergata, via Fontanile di Carcaricola, I-00156 Rome, Italy
***Dipartimento di Chimica, Universita`di Roma La Sapienza, P.le A. Moro 5, I-00185 Rome, Italy (literal)
- Titolo
- Organometallic polymer membrane for gas detection applied to a surface acoustic wave sensor (literal)
- Abstract
- The response of a surface acoustic wave (SAW) device towards relative humidity (RH) variations in the range 0-80% has been investigated. The sensor response is very fast and reproducible. The sensitive membrane is a novel organometallic polymer, poly-(bistributylphosphine)-platinum-diethylnylbiphenyl (Pt-DEBP), which has been synthesized and characterized by means of FTIR and XPS measurements. (literal)