Potential role of low kV ex vivo micro-CT for 3D morphometry of paraffin embedded coronary vessels before histology (Abstract/Comunicazione in atti di convegno)

Type
Label
  • Potential role of low kV ex vivo micro-CT for 3D morphometry of paraffin embedded coronary vessels before histology (Abstract/Comunicazione in atti di convegno) (literal)
Anno
  • 2011-01-01T00:00:00+01:00 (literal)
Alternative label
  • D. Panetta, C. Kusmic, G. Pelosi, F. Viglione, A. Del Guerra, A. L'Abbate, P.A. Salvadori (2011)
    Potential role of low kV ex vivo micro-CT for 3D morphometry of paraffin embedded coronary vessels before histology
    in ESC congress 2011, Paris, France, 27 - 31 August 2011
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • D. Panetta, C. Kusmic, G. Pelosi, F. Viglione, A. Del Guerra, A. L'Abbate, P.A. Salvadori (literal)
Pagina inizio
  • 834 (literal)
Pagina fine
  • 834 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#altreInformazioni
  • PUMA_ID: cnr.ifc/2011-A6-018 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://eurheartj.oxfordjournals.org/content/32/suppl_1.toc (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 32 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • S1 (literal)
Note
  • Abstract (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR, Pisa, Italy ; University of Pisa, Department of Physics \"E. Fermi\", Pisa, Italy ; Scuola Superiore Sant'Anna, Pisa, Italy (literal)
Titolo
  • Potential role of low kV ex vivo micro-CT for 3D morphometry of paraffin embedded coronary vessels before histology (literal)
Abstract
  • Purpose: Micro CT is an established tool for non destructive 3D inspection of small specimens. Aim of the study was to demonstrate that despite its limitations in differentiation of soft materials, micro CT can reliably display coronary vessel structure and surrounding tissues after paraffin embedding. Data were obtained from coronary specimens of pig, physical phantoms and numerical simulations. Preliminary images with dual-energy techniques are also shown. Methods: A micro CT scanner built by our group was used for the experiments. The x-ray tube was set up in the range of 20-50 kV; the voxel size was set to 21 ?m. A phantom composed of formalin fixed fat and myocardium of rat, dehydrated and paraffin embedded, was used to measure the contrast of different tissues with respect to background. Similar acquisitions were simulated numerically. Real samples of pig excised coronary arteries were processed in the same way and acquired with the same settings; resulting images were compared to those obtained by histology. Results: In phantom, the myocardium contrast vs. paraffin varied from 40% at 20 kV to 29% at 50 kV. The fat contrast vs. background was 2% at 20 kV, whereas it was indistinguishable from the background at 50 kV; all the contrasts in phantom appeared lower than those expected from simulations, probably because of tissue shrinkage. In the samples from pig (see Figure), the vessel wall contrast was 25% greater than the myocardium contrast; the pericardium and a balloon induced stenosis were clearly distinguished. All micro CT scans were shorter than 1 hour. Conclusion: Micro CT is a useful complementary tool for the 3D morphometry of coronary vessels after paraffin embedding, and it can help for the preliminary identification of features of interest for subsequent histological analysis. (literal)