http://www.cnr.it/ontology/cnr/individuo/prodotto/ID191819
OH density measurement by time-resolved broad band absorption spectroscopy in an Ar-H2O dielectric barrier discharge (Articolo in rivista)
- Type
- Label
- OH density measurement by time-resolved broad band absorption spectroscopy in an Ar-H2O dielectric barrier discharge (Articolo in rivista) (literal)
- Anno
- 2012-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1088/0022-3727/45/12/125203 (literal)
- Alternative label
Dilecce G.; Ambrico P.; Simek M.; De Benedictis S. (2012)
OH density measurement by time-resolved broad band absorption spectroscopy in an Ar-H2O dielectric barrier discharge
in Journal of physics. D, Applied physics (Print); IOP Publishing Ltd., Bristol BS1 6BE (Regno Unito)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Dilecce G.; Ambrico P.; Simek M.; De Benedictis S. (literal)
- Pagina inizio
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://iopscience.iop.org/0022-3727/45/12/125203/ (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- UOS Bari, CNR, Ist Metodol Inorgan & Plasmi, I-70125 Bari, Italy; CNR Sede Trento, Ist Mat Elettron & Magnetismo, Povo, Italy; Acad Sci Czech Republic, Inst Plasma Phys, Prague 18200, Czech Republic (literal)
- Titolo
- OH density measurement by time-resolved broad band absorption spectroscopy in an Ar-H2O dielectric barrier discharge (literal)
- Abstract
- We report results of a novel time-resolved broad-band absorption spectroscopy experiment for OH density measurement applied to a pulsed dielectric barrier discharge in Ar/H2O mixtures. The measurement is aimed at the calibration of our previous OH LIF measurements in the same discharge. The apparatus is simple and cheap, being based on a UV LED light source and a non-intensified, non-cooled, gateable linear CCD array as a detector. The set-up is capable of ruling out both medium/long-term drifts of the UV source and of the discharge, and discharge emission from the measurement. Performances of the set-up are discussed, together with possible improvements for its use as a standalone technique. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Editore di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Insieme di parole chiave di