http://www.cnr.it/ontology/cnr/individuo/prodotto/ID185295
Assessment of quantitative imaging of contaminant distributions in porous media (Articolo in rivista)
- Type
- Label
- Assessment of quantitative imaging of contaminant distributions in porous media (Articolo in rivista) (literal)
- Anno
- 2008-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1007/s00348-007-0388-x (literal)
- Alternative label
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- F. Catania; M. Massabo; M. Valle; G. Bracco; O. Paladino (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
- http://www.springerlink.com/content/u21736152kl75867/?MUD=MP (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- ISI Web of Science (WOS) (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- DIST, Dipartimento di Informatica, Sistemistica e Telematica,
University of Genova, Savona, Italy;
DIST, Dipartimento di Informatica, Sistemistica e Telematica,
University of Genova, Savona, Italy;
DIST, Dipartimento di Informatica, Sistemistica e Telematica,
University of Genova, Savona, Italy;
DIFI, Dipartimento di Fisica and CNR-IMEM,
University of Genova, Savona, Italy;
DIST, Dipartimento di Informatica, Sistemistica e Telematica,
University of Genova, Savona, Italy (literal)
- Titolo
- Assessment of quantitative imaging of contaminant distributions in porous media (literal)
- Abstract
- In this article an experimental setup designed to assist in the characterization of complex solute transport
problems in porous media is described. Glass beads representing the medium are confined in a 2-D transparent
Perspex box and a water flow transports a fluorescent dye.
Under suitable illumination, the dye emits visible light which is collected by a CCD camera. The image acquired
by this non-invasive optical technique is processed to estimate the 2-dimensional distribution of tracer concentrations by using an appropriate calibration curve that links fluorescent intensity and solute concentration. Details about the dye choice and discussion about photobleaching are reported. An analysis of the experimental error on the concentration profile is also presented. A few recent results of a study on contaminant plume within a homogenous
porous matrix constituted by glass beads having mean diameter of 1 mm or 2 mm shows the performance of
constructed model. (literal)
- Editore
- Prodotto di
- Autore CNR
- Insieme di parole chiave
Incoming links:
- Prodotto
- Autore CNR di
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
- Editore di
- Insieme di parole chiave di