Low Formaldehyde Emission Particleboard Panels Realized Through a New Acrylic Binder (Articolo in rivista)

Type
Label
  • Low Formaldehyde Emission Particleboard Panels Realized Through a New Acrylic Binder (Articolo in rivista) (literal)
Anno
  • 2011-01-01T00:00:00+01:00 (literal)
Alternative label
  • Amazio, P ; Avella, M ; Errico, ME ; Gentile, G ; Balducci, F ; Gnaccarini, A ; Moratalla, J ; Belanche, M (2011)
    Low Formaldehyde Emission Particleboard Panels Realized Through a New Acrylic Binder
    in Journal of applied polymer science (Print)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Amazio, P ; Avella, M ; Errico, ME ; Gentile, G ; Balducci, F ; Gnaccarini, A ; Moratalla, J ; Belanche, M (literal)
Pagina inizio
  • 2779 (literal)
Pagina fine
  • 2788 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 122 (literal)
Rivista
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR, ICTP, I-80078 Pozzuoli, NA, Italy. Consorzio Mobile, COSMOB, I-61100 Pesaro, Italy. Inst Tecnol Mueble Madera Embalaje & Afines, AIDIMA, Paterna 46980, Valencia, Spain. (literal)
Titolo
  • Low Formaldehyde Emission Particleboard Panels Realized Through a New Acrylic Binder (literal)
Abstract
  • The effectiveness of acrylic resins as low formaldehyde emission binders for particleboard production was explored. In particular, a multifunctional methacrylic monomer, ethoxylated bisphenol A dimethacrylate, classified as nonskin and eyes irritant, was selected and tested. In comparison panels realized with classic urea-formaldehyde (UF) binder were also prepared. No significant differences were found through the morpholocigal analysis of samples prepared with the two different binders. Moreover, particleboard panels realized with the acrylic binder showed better mechanical properties and lower water absorption and thickness swelling in comparison with corresponding panels realized with the UF binders. Furthermore, the replacement of the UF with the acrylic binder did not affect thermal insulation properties of the panels. Formaldehyde release tests revealed that particleboard panels obtained by applying the acrylic binder can be classified as E1 following the European classification and even F**** following the stricter Japanese classification. (C) 2011 Wiley Periodicals, Inc. J Appl Polym Sci 122: 2779-2788, 2011. (literal)