Direct Electrospray Ionization Mass Spectrometry Quantitative Analysis of Sebacic and Terephthalic Acids in Biodegradable Polymers (Articolo in rivista)
- Type
- Label
- Direct Electrospray Ionization Mass Spectrometry Quantitative Analysis of Sebacic and Terephthalic Acids in Biodegradable Polymers (Articolo in rivista) (literal)
- Anno
- 2011-01-01T00:00:00+01:00 (literal)
- Alternative label
P.Rizzarelli, D.Zampino, L.Ferreri, G.Impallomeni (2011)
Direct Electrospray Ionization Mass Spectrometry Quantitative Analysis of Sebacic and Terephthalic Acids in Biodegradable Polymers
in Analytical chemistry (Wash.)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- P.Rizzarelli, D.Zampino, L.Ferreri, G.Impallomeni (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#note
- ImpactFactor=5,287 (literal)
- Note
- ISI Web of Science (WOS) (literal)
- Titolo
- Direct Electrospray Ionization Mass Spectrometry Quantitative Analysis of Sebacic and Terephthalic Acids in Biodegradable Polymers (literal)
- Abstract
- A direct, rapid, and easy electrospray ionization mass spectrometry (ESI-MS) method to determine concentrations of sebacic acid (SA) and terephthalic acid (TA) residues in biodegradable copolymers was developed. Copolyester samples were synthesized from 1,4-butanediol and sebacic and terephthalic acids by melt polymerization. Extraction of monomers
was performed in methanol. Their concentrations were determined by direct infusion ESI-MS, without chromatographic separation, using 1,12-dodecanedioic acid (DDA) as an internal standard. Calibration curves were obtained by plotting the ratio of the areas of the peaks relative to monomers and DDA standard as a function of their concentration ratio. We
validated the method by determining the concentration of TA residue using both the ESI-MS protocol and high-performance liquid chromatography (HPLC) analysis with UV detection.
The linearity range and the detection limit of this assay were 0.1-5.0 and 0.01 ppm for SA and 0.1-6.0 and 0.03 ppm for TA. This assay represents a useful alternative to conventional methods currently employed for acid quantification, resulting advantageous for its speed and high sensitivity. (literal)