A simplified, flow-based calibration method for stereoscopic PIV (Articolo in rivista)
- Type
- Label
- A simplified, flow-based calibration method for stereoscopic PIV (Articolo in rivista) (literal)
- Anno
- 2010-01-01T00:00:00+01:00 (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
- 10.1007/s00348-009-0750-2 (literal)
- Alternative label
Silvano Grizzi (1); Francisco Pereira (1); Fabio Di Felice (1). (2010)
A simplified, flow-based calibration method for stereoscopic PIV
in Experiments in fluids (Print); SPRINGER, 233 SPRING ST, NEW YORK, NY 10013 (Stati Uniti d'America)
(literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
- Silvano Grizzi (1); Francisco Pereira (1); Fabio Di Felice (1). (literal)
- Pagina inizio
- Pagina fine
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
- Rivista
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
- Note
- Google Scholar (literal)
- ISI Web of Science (WOS) (literal)
- Scopu (literal)
- Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
- (1) INSEAN, Roma - Istituto Nazionale per Studi ed Esperienze di Architettura Navale (literal)
- Titolo
- A simplified, flow-based calibration method for stereoscopic PIV (literal)
- Abstract
- An improvement of the process of stereo-PIV calibration is presented. The central feature of the proposed technique is that the calibration of the stereoscopic system is based upon the measurement of a calibrated flow. This is achieved through an initial two-dimensional calibration of the measurement plane using a single target point, followed by a perspective and laser sheet thickness optimization that makes use of the measurement of a known reference flow, e.g., a uniform flow. This technique results in planar domain, three-component (2D-3C) measurements with a simpler calibration phase, which delivers uncompromised accuracy, compensates for the mechanical misalignment and eliminates the errors deriving from the classical target plate dot identification. The technique is particularly well suited for towing tanks and other large facilities, and is applied to the vortex system shed from an underwater bridge sail. (literal)