The beam position monitor of the BEAR beamline (Articolo in rivista)

Type
Label
  • The beam position monitor of the BEAR beamline (Articolo in rivista) (literal)
Anno
  • 2005-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1063/1.1926907 (literal)
Alternative label
  • Giglia, A (1); Mahne, N (1); Pedio, M (1); Nannarone, S (2); Pelizzo, MG (3); Naletto, G (3); Zambolin, P (3) (2005)
    The beam position monitor of the BEAR beamline
    in Review of scientific instruments; American Institute Of Physics (AIP), Melville (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Giglia, A (1); Mahne, N (1); Pedio, M (1); Nannarone, S (2); Pelizzo, MG (3); Naletto, G (3); Zambolin, P (3) (literal)
Pagina inizio
  • 1 (literal)
Pagina fine
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://rsi.aip.org/resource/1/rsinak/v76/i6/p063111_s1 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 76 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 5 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 063111 (literal)
Note
  • Scopu (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • (1) Laboratorio TASC-INFM - ; (2) Dipartimento di Ingegneria dei Materiali e dell'Ambiente - Universit? di Modena e Reggio Emilia; (3) LUXOR-INFM and Dipartimento di Ingegneria dell'Informazione dell'Università di Padova - (literal)
Titolo
  • The beam position monitor of the BEAR beamline (literal)
Abstract
  • This article describes the photon beam position monitor installed at the BEAR beamline at Elettra, Trieste. The device, based on four Mo photoemitting plates, is installed upstream of the beamline optics. Two modes of operation are possible, including single-plate operation sintegral moded and two-plate operation sdifferential moded. The integral mode allows beam height determination in the laboratory frame of reference with an overall accuracy of about 0.1 mm, while the differential mode features a sensitivity of the order of about 1 mm. A quantitative model connecting the device output with beam height was deduced. A satisfactory agreement was found between model predictions and experimental results. The quantitative performance opens the possibility to implement a feedback procedure to stabilize or automatically numerically correct the delivered photon energy. (literal)