Subjective evaluation of a simple active noise control system mounted inside an earth moving machine cab (Articolo in rivista)

Type
Label
  • Subjective evaluation of a simple active noise control system mounted inside an earth moving machine cab (Articolo in rivista) (literal)
Anno
  • 2009-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.3397/1.3155379 (literal)
Alternative label
  • Eleonora Carletti; Francesca Pedrielli (2009)
    Subjective evaluation of a simple active noise control system mounted inside an earth moving machine cab
    in Noise control engineering journal; Institute Of Noise Control Engineering, Ames (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Eleonora Carletti; Francesca Pedrielli (literal)
Pagina inizio
  • 595 (literal)
Pagina fine
  • 602 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://incedl.org/nce/resource/1/ncejd5/v57/i6/p595_s1 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 57 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 8 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 6 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopu (literal)
  • Google Scholar (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • Istituto Imamoter CNR (literal)
Titolo
  • Subjective evaluation of a simple active noise control system mounted inside an earth moving machine cab (literal)
Abstract
  • A series of experiments were carried out in order to verify the feasibility of an active noise control (ANC) approach to improve the acoustic comfort at the operator's station of a compact loader. For this kind of application expensive noise control solutions would be too expensive for the market and therefore unsuitable. Hence, a very simple active noise control layout using a single channel feed-forward scheme was used. Its capability to reduce the dominant low frequency noise components and the overall level within the space where the operator's head is located during his/her work was experimentally verified. Then, the modifications caused by this ANC system were subjectively evaluated with regards to some important noise features (tiredness, concentration loss, loudness and booming sensation) in order to qualify comfort and working safety conditions for the operator. (literal)
Editore
Prodotto di
Autore CNR
Insieme di parole chiave

Incoming links:


Autore CNR di
Prodotto
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#rivistaDi
Editore di
Insieme di parole chiave di