Laboratory activity for a new procedure of MIVIS calibration and relative validation with test data (Articolo in rivista)

Type
Label
  • Laboratory activity for a new procedure of MIVIS calibration and relative validation with test data (Articolo in rivista) (literal)
Anno
  • 2006-01-01T00:00:00+01:00 (literal)
Alternative label
  • Bassani C; Cavalli R M; Madonna F; Palombo A; Pignatti S (2006)
    Laboratory activity for a new procedure of MIVIS calibration and relative validation with test data
    in Annals of geophysics (Testo stamp.)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Bassani C; Cavalli R M; Madonna F; Palombo A; Pignatti S (literal)
Pagina inizio
  • 45 (literal)
Pagina fine
  • 56 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 49 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 12 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 1 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • CNR - IIA - LARA CNR - IMAA (literal)
Titolo
  • Laboratory activity for a new procedure of MIVIS calibration and relative validation with test data (literal)
Abstract
  • Remotely sensed data, recorded by means of the MIVIS hyperspectral scanner in the framework of the research activity of the CNR Institutes IIA-LARA and IMAA, have been calibrated to reflec-tance values and then quantitatively compared with ground data. A new procedure for radiometric calibration has been defined by utilizing the MIVIS test-bench and applying a wider radiance range with respect to the one provided by the manufacturing company. New calibration curves have been determined and applied in the pre-processing chain. For validation purpose ground spectra were measured during campaign by means of a portable spec-troradiometer. The atmospheric correction has been carried out by implementing an IDL procedure to manage MODTRAN4 input and output cards. MIVIS test data acquired over Passo Corese (Roma) have shown how the new calibration coeffi-cients significantly improve the radiometric accuracy. In particular, in the VIS spectral region the percentage error, with respect to a ground truth spectrum, is about the half of that occurring if the standard calibration coefficients are used. (literal)