Accuracy of sonographic volume measurements of kidney transplant. (Articolo in rivista)

Type
Label
  • Accuracy of sonographic volume measurements of kidney transplant. (Articolo in rivista) (literal)
Anno
  • 2006-01-01T00:00:00+01:00 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#doi
  • 10.1002/jcu.20212 (literal)
Alternative label
  • Marcello Mancini, MD,1 Pier Paolo Mainenti, MD,1 Antonio Speranza, PhD,1 Raffaele Liuzzi, PhD,1 Ernesto Soscia, MD,1 Massimo Sabbatini, MD,2 Liberato Aldo Ferrara, MD,3 Stefano Federico, MD,2 Marco Salvatore, MD4 (2006)
    Accuracy of sonographic volume measurements of kidney transplant.
    in Journal of clinical ultrasound (Print); WILEY-LISS, DIV JOHN WILEY & SONS INC, 111 RIVER ST, HOBOKEN, NJ 07030 (Stati Uniti d'America)
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Marcello Mancini, MD,1 Pier Paolo Mainenti, MD,1 Antonio Speranza, PhD,1 Raffaele Liuzzi, PhD,1 Ernesto Soscia, MD,1 Massimo Sabbatini, MD,2 Liberato Aldo Ferrara, MD,3 Stefano Federico, MD,2 Marco Salvatore, MD4 (literal)
Pagina inizio
  • 184 (literal)
Pagina fine
  • 189 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 34 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 6 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroFascicolo
  • 4 (literal)
Note
  • ISI Web of Science (WOS) (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1 Biostructure and Bioimaging Institute, National Research Council, Istituto di Biostrutture e Bioimmagini-CNR, Via S. Pansini, 5 Ed. 10, 80131 Naples, Italy 2 Institute of Medical Nephrology, Medical School ''Federico II'', University of Naples, Via Pansini, 5 Ed. 10, 80131 Naples, Italy 3 Department of Cinical and Experimental Medicine, Medical School ''Federico II'', University of Naples, Via Pansini, 5 Ed. 10, 80131 Naples, Italy 4 Diagnostic Imaging Department, Medical School ''Federico II'', University of Naples, Via Pansini, 5 Ed. 10, 80131 Naples, Italy (literal)
Titolo
  • Accuracy of sonographic volume measurements of kidney transplant. (literal)
Abstract
  • ABSTRACT: Purpose. Sonographic measurement of renal volume is one of the parameters used in the diagnosis of renal transplant dysfunction and in follow- up of patients with renal transplant. The aim of this study was to compare the prolate ellipsoid formula with a new formula in calculating the volume of a transplanted kidney. Methods. The renal volumes in 24 patients with a stable renal transplant were determined sonographically with the ellipsoid formula and via helical CT with the voxel-count method, which is the gold standard. A new formula that uses renal length and the cross-sectional area at themaximumtransverse section has been evaluated in a small series of transplanted kidneys. Results. Renal volume was underestimated with the sonographic ellipsoid formula and the new formula. The new formula yielded the lowest underestimation of the mean renal volume, and the measurements obtained with it were not significantly different from those obtained with CT. Conclusions. The use of sonography is appropriate for accurate calculation of renal volume, and the new formula that uses only 2 ultrasound parameters best represents the volume of a renal transplant (literal)